42250
Streptavidin-Phycoerythrin
≥1 mg/mL (active substance)
Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme
About This Item
Produits recommandés
Forme
liquid
Concentration
≥1 mg/mL (active substance)
Fluorescence
λex 566 nm; λem 576 nm in 0.1 M phosphate pH 7.0
Température de stockage
2-8°C
Description générale
Streptavidin-R-Phycoerythrin is a fluorescent labeling agent comprised of a biotin-binding protein (streptavidin) covalently attached to a fluorescent label ((R-phycoerythrin). Streptavidin-R-phycoerythrin complexes provide the measurement method for the target phosphoprotein. And, Streptavidin R-phycoerythrin extends the light tolerance of certain phycobiliproteins.
Application
Streptavidin-R-Phycoerythrin (R-PE) is used to label biotin-conjugated (biotinylated) molecules and biotin derivatized surfaces in a wide variety of immunofluorescence applications such as immunochemistry and histochemistry. Streptavidin-R-Phycoerythrin may be used in the development of bioassay devices such as Lab-on-a-chip (LoC) systems and microarrays.
Informations légales
Geniom is a registered trademark of Febit Biotech GmbH
Code de la classe de stockage
12 - Non Combustible Liquids
Classe de danger pour l'eau (WGK)
WGK 1
Point d'éclair (°F)
Not applicable
Point d'éclair (°C)
Not applicable
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Malaria journal, 19(1), 188-188 (2020-05-26)
While sub-microscopic malarial infections are frequent and potentially deleterious during pregnancy, routine molecular detection is still not feasible. This study aimed to assess the performance of a Histidine Rich Protein 2 (HRP2)-based ultrasensitive rapid diagnostic test (uRDT, Alere Malaria Ag
Biomedical microdevices, 13(5), 819-827 (2011-05-24)
Point-of-care (PoC) testing followed by personalized efficient therapy of infectious diseases may result in a considerable reduction of associated health care costs. Lab-on-a-chip (LoC) systems represent a potentially high efficient class of PoC tools. Here, we present a LoC system
Steroids, 75(13-14), 1089-1096 (2010-07-27)
The small blood volumes available in rodent studies often limit adequate quantification of all hormones of interest. We report here the development of two new assays combining an extraction step with multiplex immunoassay (MIA) technology for the simultaneous determination of
Clinical chemistry, 52(6), 1033-1039 (2006-03-25)
Genotyping of N-acetyltransferase-2 (NAT2) is useful in predicting the risk for toxicity of NAT2 substrates. Current methods cannot detect the 7 most important single-nucleotide variations in NAT2 simultaneously in 1 tube. We developed an assay that uses allele-specific primer extension
Light tolerance of R-phycoerythrin and a tandem conjugate observed by single molecule recrossing events.
Appl. Spectroscopy, 63, 709-715 (2009)
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique