Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

K003A05FF1

Millipore

Opticap® XL Capsule Filter

pore size 0.3 μm, cartridge nominal length 5 in. (12.5 cm), filter diam. 4.2 in. (10.7 cm)

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
23151806

Matériaux

polypropylene filter
polypropylene housing
polypropylene support
silicone seal

Niveau de qualité

Conformité réglementaire

meets FDA 21 CFR 177-182 (all component materials)

Fabricant/nom de marque

Opticap®

Paramètres

max. inlet temp. at 25 °C
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
4.8 bar max. differential pressure (70 psid) at 20 °C
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure

Longueur nominale des cartouches

5 in. (12.5 cm)

device size

5 in.

filter L

8.5 in. (21.6 cm)

Diam. du filtre

4.2 in. (10.7 cm)

Diam. du raccord d'entrée

3/4 in. , sanitary flange

inlet to outlet width

21.6 cm (8.5 in.)

Impuretés

≤0.25 EU/mL USP bacterial endotoxins (LAL test, aqueous extraction)

Matrice

Clarigard®

Dimension de pores

0.3 μm pore size

Raccords

inlet/outlet connection for 19 mm (3/4 in.) sanitary flange

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Cartridge Type: Liquid
Device Configuration: Capsule

Conditionnement

Double Easy-Open bag

Notes préparatoires

Sterilization Method:
3 autoclave cycles of 30min at 126°C; not in-line steam sterilizable
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21CFR210.3(b)(6).

Remarque sur l'analyse

Gravimetric Extractables: ≤ 55mg per capsule after 24 hours in water at controlled room temperature.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2L

Autres remarques

Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

Informations légales

CLARIGARD is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique