MILLIPLEX® Human Amyloid Beta and Tau Magnetic Bead Panel - Multiplex Assay

allows quantitative multiplex detection of multiple analytes simultaneously

Synonyme(s) :

Human Neuroscience Protein Multiplex Assay, Luminex® Human Neuroscience Panel, Millipore Human Neuroscience Immunoassay

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12161503
eCl@ss :
32161000
Nomenclature NACRES :
NA.84

Niveau de qualité

Espèces réactives

human

Fabricant/nom de marque

Milliplex®

assay range

accuracy: 109%
(Spike recovery for Aβ1-42)

accuracy: 91%
(Spike recovery for pTau181)

accuracy: 98%
(Spike recovery for tTau)

sensitivity: 1.5 pg/mL
(pTau181; MinDC+2SD)

sensitivity: 10.2 pg/mL
(A?1-40; MinDC+2SD)

sensitivity: 14.2 pg/mL
(tTau; MinDC+2SD)

sensitivity: 2.5 pg/mL
(A?1-42; MinDC+2SD)

standard curve range: 0.7-500 pg/mL
(pTau181)

standard curve range: 11-8000 pg/mL
(tTau)

standard curve range: 2-2000 pg/mL
(Aβ1-42)

standard curve range: 21-15000 pg/mL
(Aβ1-40)

inter-assay cv: <15%
intra-assay cv: <10%

Technique(s)

multiplexing: suitable

Méthode de détection

fluorometric (Luminex xMAP)

Conditions d'expédition

wet ice

Description générale

MILLIPLEX® Human Amyloid Beta and Tau Panel enables you to focus on the relevance and therapeutic potential of Aβ40, Aβ42, Total Tau proteins (tTau), and Phosphorylated Tau Thr181 (pTau181) in your research model. Coupled with the Luminex® xMAP® platform in a bead format, you receive the advantage of ideal speed and sensitivity, allowing quantitative multiplex detection of multiple analytes simultaneously, which can dramatically improve productivity.

The MILLIPLEX® Human Amyloid Beta Tau Bead Panel is to be used for the simultaneous quantification of Aβ40, Aβ42, tTau, and pTau181. This kit may be used only for the analysis of cerebrospinal fluid (CSF). This is a configurable assay, and some or all analytes can be selected: tau (total), amyloid β40, amyloid β42 and tau (pThr181).

MILLIPLEX® portfolio offers the broadest selection of analytes across a wide range of disease states and species. Once the analytes of interest have been identified, you can rely on the quality that we build into each kit to produce results you can trust. In addition to the assay characteristics listed in the protocol, other performance criteria evaluated during the validation process include: cross-reactivity, dilution linearity, kit stability and sample behavior (e.g. detectability and stability). Each panel and kit meets stringent manufacturing criteria to ensure batch-to-batch reproducibility.

Each MILLIPLEX® panel and kit includes:
• Quality controls (QCs) provided to qualify assay performance
• Comparison of standard (calibrator) and QC lots to a reference lot to ensure lot-to-lot consistency
• Optimized serum matrix to mimic native analyte environment
• Detection antibody cocktails designed to yield consistent analyte profiles within panel

MILLIPLEX® Human Amyloid Beta Tau Bead Panel is part of the most versatile system available for cytokine research. From our single to multiplex biomarker solutions, we partner with you to design, develop, analytically validate, and build the most comprehensive library available for protein detection and quantitation.

Panel Type: Neuroscience

Spécificité

Cross Reactivty
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes within a panel.

Application

  • Analytes: Tau (Total), Amyloid β40, Amyloid β42, Tau (pThr181)
  • Recommended Sample type: cerebrospinal fluid (CSF)
  • Recommended Sample dilution: 1:2 sample dilution is recommended for extracted CSF samples
  • Assay Run Time: Overnight
  • Research Category: Neuroscience Metabolism
  • Research Subcategory: Metabolic Disorders Obesity Inflammation & Autoimmune Mechanisms
  • Research Category Neuroscience Metabolism
  • NOTE: This is a competitive assay

Caractéristiques et avantages

Design your multiplex kit by choosing available analytes within this panel.

Conditionnement

96-well plate
Everything you need in a single kit.

Composants

Human ABeta and Tau Standard, 1 vial, lyophilized

Human ABeta and Tau Quality Control 1, 1 vial, lyophilized

Human ABeta and Tau Quality Control 2, 1 vial, lyophilized

Bead Diluent, 1 bottle, 3.5mL

Set of one 96-Well Plate with 2 sealers

Assay Buffer, 1 bottle, 30 mL

Wash Buffer, 10X (0.05% Proclin), 2 bottles, 30 mL ea

Human ABeta and Tau Detection Antibodies, 1 bottle, 3.2 mL

Streptavidin-Phycoerythrin, 1 bottle, 3.2 mL

Mixing Bottle, 1 bottle

Stockage et stabilité

Recommended storage for kit components is 2 - 8°C.

Informations légales

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Clause de non-responsabilité

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Pictogrammes

Skull and crossbonesEnvironment

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1

Code de la classe de stockage

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Mohamed Raâfet Ben Khedher et al.
Alzheimer's & dementia (New York, N. Y.), 7(1), e12124-e12124 (2021-02-05)
In brain, extracellular vesicles (EVs) play an essential role in the neuron-glia interface and ensure the crosstalk between the brain and the periphery. Some studies now link the pathway dysfunction of the EVs to apolipoprotein E gene variant (APOE ε4)
Jessica L Hoffman et al.
International review of neurobiology, 148, 169-230 (2019-11-18)
Alzheimer's disease (AD) is a progressive neurodegenerative disorder that represents the most common cause of dementia in the United States. Although the link between alcohol use and AD has been studied, preclinical research has potential to elucidate neurobiological mechanisms that
Wencheng Yin et al.
Frontiers in neuroscience, 14, 602642-602642 (2021-01-05)
Alzheimer's disease (AD)-related degenerative decline is associated to the presence of amyloid beta (Aβ) plaque lesions and neuro fibrillary tangles (NFT). However, the precise molecular mechanisms linking Aβ deposition and neurological decline are still unclear. Here we combine genome-wide transcriptional
Francheska Delgado-Peraza et al.
Cells, 10(5) (2021-05-01)
Circulating neuronal extracellular vesicles (NEVs) of Alzheimer's disease (AD) patients show high Tau and β-amyloid (Aβ) levels, whereas their astrocytic EVs (AEVs) contain high complement levels. To validate EV proteins as AD biomarkers, we immunocaptured NEVs and AEVs from plasma
Emma L Robertson et al.
Alzheimer's & dementia (New York, N. Y.), 8(1), e12289-e12289 (2022-04-14)
Monkeys are becoming important translational models of neurodegenerative disease. To facilitate model development, we measured cerebrospinal fluid (CSF) concentrations of key biomarkers in healthy male and female cynomolgus and rhesus macaques. Amyloid beta (Aβ40, Aβ42), tau (total tau [t-tau], phosphorylated

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique