Sélectionner une taille de conditionnement
A propos de cet article
Quality Segment
material
polyethersulfone membrane, polypropylene housing, polypropylene support, polypropylene vent cap
reg. compliance
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterility
non-sterile
sterilization compatibility
autoclavable compatible
steam-in-place compatible
product line
EMPROVE® Filter, Milligard®
feature
hydrophilic
manufacturer/tradename
Milligard®
parameter
1.38 bar max. differential pressure (20 psid) at 25 °C (Reverse), 5.52 bar max. differential pressure (80 psid) at 4-25 °C (Forward)
technique(s)
prefiltration: suitable
L
317.5 mm (12.5 in.)
W
2.7 in.
cartridge nominal length
10 in. (25 cm)
diam.
69 mm (2.71 in.)
filtration area
0.6 m2
impurities
<0.25 EU/mL bacterial endotoxins (LAL test, per device; aqueous extraction; meeting requirements of USP <85>, EP 2.6.14 and JP 4.01)
matrix
Milligard® PES
pore size
1.2/0.45 μm pore size
input
sample type liquid
cartridge code
Code 7
General description
Preparation Note
Autoclave wet 25x, 60 minute cycles at 128°C. In-line steam (wet): 10 forward cycles, 30 min.,
135 °C at ≤0.34 bar (5 psid) and 5 reverse cycles,
30 min., 135 °C at ≤0.07 bar (<1 psid)*.
*Devices were validated using steam at full differential pressure starting at 31 psid to a final differential pressure of 1 psid, resulting in a calculated average of 4 psid in forward and reverse directions.
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer wetting instructions of Filters with MILLIGARD® PES Membrane user guide
- Storage Statement: Please refer Filters with MILLIGARD® PES Membrane user guide
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Legal Information
Still not finding the right product?
Explore all of our products under Cartouche Milligard® II en PES de 1,2/0,45 µm
Restez en conformité avec les BPF grâce au programme Emprove®.
Accélérer la qualification, maintenir la conformité et gagner du temps avec Emprove® Dossiers.
Note: you will be brought to EmproveSuite.com. Your username and password are separate from SigmaAldrich.com and may differ.
Inscrivez-vous gratuitement et accédez à Emprove® Dossiers en quelques minutes. Mettez votre abonnement à niveau pour débloquer un contenu avancé et personnalisé dans la Emprove® Suite
Vous ne trouvez pas ce que vous cherchez ? Visitez la page d'aide du programme Emprove®..
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.