1.05616
HPTLC plates, Silica gel F₂₅₄
pkg of 25 plates, plate L × W 5 cm × 10 cm, glass support
Synonyme(s) :
Silica F₂₅₄ Chromatography Plates
About This Item
Produits recommandés
Matériaux
glass support
silica gel 60 matrix
Niveau de qualité
Caractéristiques
binder Organic Polymer
fluorescent indicator
Conditionnement
pkg of 25 plates
Technique(s)
thin layer chromatography (TLC): suitable
Épaisseur de la couche
200 μm
Plaque/Plateau, L × l
5 cm × 10 cm
Taille des particules
5-6 μm
Dimension de pores
60 Å medium pore diameter
Température de stockage
2-30°C
Description générale
Application
- Stability indicating high performance thin layer chromatography method development and validation for quantitative determination of tetracycline hydrochloride: In this study, the use of Silica gel F₂₅₄ HPTLC plates is optimized for analyzing tetracycline hydrochloride in pharmaceutical forms. This method serves as a stability-indicating test, crucial for ensuring the safety and efficacy of this common antibiotic, highlighting the material′s importance in regulatory compliance and drug development (Gashaw et al., 2024).
- Robust high-performance thin-layer chromatography (HPTLC) method for stability assessment and simultaneous quantification of epigallocatechin-3-gallate and rosmarinic acid in lipid-based nanoparticles and biological matrices: This research uses Silica gel F₂₅₄ HPTLC plates to develop a high-performance chromatographic method for assessing the stability and concentration of bioactive compounds in complex samples. The technique is essential for advanced material science and biomedical research, providing accurate and reproducible results (Koli et al., 2024).
Liaison
Remarque sur l'analyse
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 150 - 200 µm
Deviation of layer thickness per plate: ≤ 35 µm
Chromatographic testings:
A) Colour test
hRf-values
- bleu vif organol, colour test, lipophile:
17 - 22
- Ceres Black G, colour test, lipophile: 38 - 43
- ceres Violet brn, colour test, lipophile: 58 - 64
separation number
- colourtest, lipophile:
≥ 10.0
B) Steriod test
hRf-values
- hydrocortisone, steroid test:
23 - 29
- Reichstein S, steroid test: 36 - 45
- methyltestosterone, steroid test: 43 - 52
separation number
- steroid test:
≥ 10.5
Typical value determined on a conditioned plate
Eluent A) Toluene (45% rel.humidity)
Eluent B) Ethyl acetate/Toluene (95+5 v/v; 20% rel.humidity)
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique