Skip to Content
MilliporeSigma
All Photos(1)

Documents

RAB0096

Sigma-Aldrich

Human C-Reactive Protein ELISA Kit

for serum, plasma, cell culture supernatants and urine

Synonym(s):

C-reactive protein, CRP

Sign Into View Organizational & Contract Pricing


About This Item

UNSPSC Code:
41116158
NACRES:
NA.32

species reactivity

human

packaging

kit of 96 wells (12 strips x 8 wells)

technique(s)

ELISA: suitable
capture ELISA: suitable

input

sample type cell culture supernatant(s)
sample type urine
sample type serum
sample type plasma

assay range

inter-assay cv: <12%
intra-assay cv: <10%
sensitivity: 34 pg/mL
standard curve range: 34.29-25000 pg/mL

detection method

colorimetric

shipped in

wet ice

storage temp.

−20°C

Gene Information

human ... CRP(1401)

General description

The Human CRP (C Reactive Protein) ELISA (Enzyme- Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of human CRP in serum, plasma, cell culture supernatants and urine.

Immunogen

Recombinant Human CRP

Application

Human C-Reactive Protein ELISA Kit has been used to measure C-reactive protein (CRP) levels in serum.

Biochem/physiol Actions

C-reactive protein (CRP) is part of the pentraxin protein family and is synthesized in the liver. It is a marker of systemic inflammation and may also have a role in atherosclerosis, stroke and myocardial infarction. Levels of CRP increase during tissue damage and trauma. The protein acts as an opsonin and binds to phospholipids on tumor cell membranes. This may lead to lysis of tumor cells. CRP is also a biomarker of age-related macular degeneration (AMD).

Other Notes

A sample Certificate of Analysis is available for this product.
Please type the word sample in the text box provided for lot number.

Kit Components Also Available Separately

Product No.
Description
SDS

  • RABELADBELISA 5X Assay/Sample Diluent Buffer B (Item E1)SDS

  • RABELADDELISA 5X Assay/Sample Diluent Buffer D (Item K)SDS

  • RABSTOP3ELISA Stop Solution (Item I)SDS

  • RABTMB3ELISA Colorimetric TMB Reagent (HRP Substrate, Item H)SDS

  • RABWASH420X Wash Buffer (Item B)SDS

Pictograms

Corrosion

Signal Word

Warning

Hazard Statements

Precautionary Statements

Hazard Classifications

Met. Corr. 1

Storage Class Code

8A - Combustible corrosive hazardous materials


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Ying Liu et al.
Experimental and therapeutic medicine, 15(1), 585-591 (2018-02-02)
The objective of the present study was to investigate the role of Toll-like receptor (TLR)-9 in B lymphocyte stimulating factor (BLyS)-induced systemic lupus erythematosus (SLE) in mice. The anti-double stranded (ds)DNA antibody titer, levels of complement proteins (C3 and C4)
Adsorbing/dissolving Lyoprotectant Matrix Technology for Non-cryogenic Storage of Archival Human Sera
Solivio MJ, et al.
Scientific Reports, 6, 24186-24186 (2016)
Biomarker and shear stress in secondary pediatric pulmonary hypertension
Pektacs A, et al.
Turkish Journal of Medical Sciences, 47(6), 1854-1860 (2017)
Loci Related to Metabolic-Syndrome Pathways Including LEPR,HNF1A, IL6R, and GCKR Associate with Plasma C-Reactive Protein: The Women's Genome Health Study
Paul M.Ridker
Cell (2008)
Azza M Elamir et al.
Biomedical reports, 15(5), 93-93 (2021-10-12)
The aim of the present study was to detect the serum levels of long non-coding RNA (lncRNA) growth arrest-specific 5 (GAS5) in patients with rheumatoid arthritis (RA) and healthy controls, and determine the association between the rs2067079, rs6790, and rs17359906

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service