Saltar al contenido
Merck
Todas las fotos(1)

Documentos clave

48734

Supelco

Aroclor 1254 solution

certified reference material, 50 mg/kg in transformer oil

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Número de CAS:
Número MDL:
Código UNSPSC:
12000000

grado

certified reference material
TraceCERT®

Nivel de calidad

Línea del producto

TraceCERT®

CofA

current certificate can be downloaded

envase

ampule of 5 mL

concentración

50 mg/kg in transformer oil

técnicas

HPLC: suitable
gas chromatography (GC): suitable

aplicaciones

environmental

Formato

single component solution

temp. de almacenamiento

2-30°C

cadena SMILES

Clc1c(c(ccc1Cl)c2c(c(ccc2)Cl)Cl)Cl

InChI

1S/C12H5Cl5/c13-8-3-1-2-6(10(8)15)7-4-5-9(14)12(17)11(7)16/h1-5H

Clave InChI

AUGNBQPSMWGAJE-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Aplicación

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Otras notas

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Información legal

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictogramas

Health hazardEnvironment

Palabra de señalización

Danger

Frases de peligro

Clasificaciones de peligro

Aquatic Chronic 2 - Carc. 1B - STOT RE 2

Código de clase de almacenamiento

6.1C - Combustible, acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

Clase de riesgo para el agua (WGK)

WGK 3

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable

Equipo de protección personal

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Si necesita más asistencia, póngase en contacto con Atención al cliente

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Los clientes también vieron

Slide 1 of 1

1 of 1

Jing An et al.
Toxicology, 295(1-3), 8-14 (2012-03-13)
Polychlorinated biphenyls (PCBs) are still prevalent in the environment despite the fact that they have been banned in many countries for several decades. Recent epidemiologic studies have demonstrated a link between PCBs exposure and pathological alterations of bone tissues. The
L A Martin et al.
Drug metabolism and disposition: the biological fate of chemicals, 40(3), 588-595 (2011-12-22)
Polychlorinated biphenyl (PCB) congeners differentially reduce serum thyroxine (T(4)) in rats, but little is known about their ability to affect biliary excretion of T(4). Thus, male Sprague-Dawley rats were orally administered Aroclor-1254, Aroclor-1242 (32 mg/kg per day), PCB-95, PCB-99, PCB-118
Jiali Cai et al.
Toxicology, 287(1-3), 21-28 (2011-06-15)
The testicular toxicity of polychlorinated biphenyls (PCBs) has been extensively studied. However, the detailed mechanism is still obscure. In the present study, male C57 mice were treated with different doses of Aroclor 1254 (a commercial PCB mixture) once every 3
Hamdy A A Aly
Environmental toxicology and pharmacology, 36(2), 274-283 (2013-05-21)
Aroclor 1254, a commercial mixture of highly toxic environmental pollutant, is known to cause testicular toxicity. The present study was undertaken to delineate and elucidate the nature and the mechanism of action of Aroclor 1254 on rat sperm in vitro.
Cyril Rigaud et al.
Aquatic toxicology (Amsterdam, Netherlands), 149, 133-144 (2014-03-13)
The 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) toxic equivalent quantity (TCDD-TEQ) approach was used successfully to predict lethal embryotoxicity in salmonids, but its applicability to sublethal effects of mixtures of organohalogenated compounds in other fish species is poorly known. The sublethal toxicity of two

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico