Saltar al contenido
Merck

10771

Sigma-Aldrich

Histopaque®-1077

sterile-filtered, density: 1.077 g/mL

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

UNSPSC Code:
12352207
NACRES:
NA.75

sterility

sterile-filtered

Quality Level

form

liquid

shelf life

Expiry date on the label.

impurities

endotoxin, tested

density

1.077 g/mL

application(s)

hematology
histology

storage temp.

2-8°C

General description

Histopaque-1077 es un medio estéril, probado para endotoxinas y listo para usar. La composición de Histopaque consiste en polisacarosa y diatrizoato de sodio, ajustados a una densidad de 1,077 g/ml. Este medio listo para usar facilita la recuperación rápida de los linfocitos viables y otras células mononucleares de pequeños volúmenes de sangre completa o médula ósea.

Application

Histopaque-1077 se ha utilizado para:
  • la determinación de los antígenos del complejo principal de histocompatibilidad (HLA)
  • como etapa inicial del aislamiento antes del recuento de linfocitos T, B y ‘nulos’.
  • preparación de suspensiones puras de linfocitos para cultivos celulares y ensayos de citotoxicidad.
  • Aislamiento y purificación de células mononucleares de sangre periférica (PBMC) y células mononucleares de médula ósea (BMMC)
  • aislamiento de linfocitos humanos
  • aislamiento de células tumorales circulantes de cáncer de mama (CTC) en sangre completa
  • Histopaque-1077 se utiliza junto con Histopaque-1119 ya que facilita la recuperación rápida de células mononucleares viables y granulocitos de pequeños volúmenes de sangre completa

Features and Benefits

Histopaque®-1077 ofrece numerosas ventajas, como:
  • Recuperación óptima de las células viables
  • Permite la separación selectiva de los tipos de células sanguíneas
  • Previene la distorsión celular
  • Preserva la viabilidad celular
  • Interferencia mínima de células extrañas
  • Rendimiento reproducible de lote a lote
  • Esterilizado mediante filtración y probado para endotoxinas
  • Estable a 2-8°C durante al menos 2 años cuando está protegido de la luz

Principle

La sangre anticoagulada se coloca en capas sobre el Histopaque-1077. Durante la centrifugación, la polisacarosa produce agregación de los eritrocitos, que sedimentan rápidamente. Los granulocitos se vuelven ligeramente hipertónicos, lo que aumenta su velocidad de sedimentación y provoca su depósito en el fondo del tubo de centrífuga. Los linfocitos y otras células mononucleares permanecen en la interfaz plasma/Histopaque-1077.

Legal Information

Histopaque is a registered trademark of Merck KGaA, Darmstadt, Germany

pictograms

Health hazard

signalword

Danger

hcodes

Hazard Classifications

Resp. Sens. 1 - Skin Sens. 1

Storage Class

12 - Non Combustible Liquids

wgk_germany

WGK 3


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Evaluation of respiration with clark type electrode in isolated mitochondria and permeabilized animal cells.
Silva AM and Oliveira PJ
Methods in Molecular Biology, 810, 7-24 (2012)
Erin E Thacker et al.
Vaccine, 27(50), 7116-7124 (2009-09-30)
Targeting viral vectors encoding tumor-associated antigens to dendritic cells (DCs) in vivo is likely to enhance the effectiveness of immunotherapeutic cancer vaccines. We have previously shown that genetic modification of adenovirus (Ad) 5 to incorporate CD40 ligand (CD40L) rather than
Maria Björkqvist et al.
The Journal of experimental medicine, 205(8), 1869-1877 (2008-07-16)
Huntington's disease (HD) is an inherited neurodegenerative disorder characterized by both neurological and systemic abnormalities. We examined the peripheral immune system and found widespread evidence of innate immune activation detectable in plasma throughout the course of HD. Interleukin 6 levels
Ana C Leal et al.
Scientific reports, 7(1), 6438-6438 (2017-07-27)
Cancer patients are at an increased risk of developing thromboembolic complications. Several mechanisms have been proposed to explain cancer-associated thrombosis including the release of tumor-derived extracellular vesicles and the activation of host vascular cells. It was proposed that neutrophil extracellular
Romain A Colas et al.
Journal of immunology (Baltimore, Md. : 1950), 197(11), 4444-4452 (2016-11-02)
Maresin 1 (MaR1) is an immunoresolvent that governs resolution of acute inflammation, and its local metabolism in the context of infectious inflammation is of interest. In this study, we investigated the MaR1 metabolome in infectious exudates and its bioactions in

Artículos

Centrifugation enables the separation of particles by sedimentation. Learn how to separate particles using a centrifuge and how to use Stokes' law to calculate the velocity of sedimentation.

Centrifugation enables the separation of particles by sedimentation. Learn how to separate particles using a centrifuge and how to use Stokes' law to calculate the velocity of sedimentation.

Centrifugation enables the separation of particles by sedimentation. Learn how to separate particles using a centrifuge and how to use Stokes' law to calculate the velocity of sedimentation.

Centrifugation enables the separation of particles by sedimentation. Learn how to separate particles using a centrifuge and how to use Stokes' law to calculate the velocity of sedimentation.

Protocolos

This troubleshooting guide addresses the most common sources of error observed when using Histopaque but is not meant to be a comprehensive list.

Ficoll 400® is a non-ionic polymer with high hydrophilicity and water solubility, suitable for various biological applications.

Ficoll 400® is a non-ionic polymer with high hydrophilicity and water solubility, suitable for various biological applications.

Ficoll 400® is a non-ionic polymer with high hydrophilicity and water solubility, suitable for various biological applications.

Ver todo

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.