Saltar al contenido
Merck

374350

Sigma-Aldrich

Tridodecylmethylammonium iodide

97%

Sinónimos:

Methyltridodecylammonium iodide

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula lineal:
[CH3(CH2)11]3N(I)CH3
Número de CAS:
Peso molecular:
663.93
Beilstein/REAXYS Number:
4260774
MDL number:
UNSPSC Code:
12352116
PubChem Substance ID:
NACRES:
NA.22

Quality Level

assay

97%

mp

106-107 °C (lit.)

SMILES string

[I-].CCCCCCCCCCCC[N+](C)(CCCCCCCCCCCC)CCCCCCCCCCCC

InChI

1S/C37H78N.HI/c1-5-8-11-14-17-20-23-26-29-32-35-38(4,36-33-30-27-24-21-18-15-12-9-6-2)37-34-31-28-25-22-19-16-13-10-7-3;/h5-37H2,1-4H3;1H/q+1;/p-1

InChI key

JRLISGAUAJZAGL-UHFFFAOYSA-M

¿Está buscando productos similares? Visita Guía de comparación de productos

Application

Tridodecylmethylammonium iodide (3C12MAI) can be used:
  • As a triple-chained cationic surfactant.
  • to prepapre glucose oxidase enzyme immobilized iodide electrode for the detection of glucose concentration.
  • As a cationic phase-transfer catalyst in the oxidation of hydrocarbons by O2.

Storage Class

11 - Combustible Solids

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

The role of onium salts in the oxidation of hydrocarbons by O 2 catalysed by cationic phase-transfer reagents
Csanyi L, et al.
Physical Chemistry Chemical Physics, 2(17), 3801-3805 (2000)
Effect of cyclodextrins on the stability of bilayer: A novel electrophoretic approach
Zandkarimi M, et al.
Journal of Liquid Chromatography and Related Technologies, 37(17), 2433-2443 (2014)
Preparation and application of a new glucose sensor based on iodide ion selective electrode
K Sukru, et al.
Talanta, 65(1), 87-91 (2005)
A J Hamilton et al.
Neurosurgery, 40(5), 1043-1049 (1997-05-01)
The biotoxicity of tri-iododecyclemethyl ammonium chloride (TDMAC)-coated catheters in the brain was tested, as was the efficacy of the vancomycin-bonded, TDMAC-coated catheters to inhibit staphylococcal growth in vitro and to delay the onset of clinical manifestations of catheter-related staphylococcal ventriculitis
Monika Mroczkiewicz et al.
Talanta, 85(4), 2047-2052 (2011-08-30)
In this work, flow-injection system with potentiometric detection was tested for determination of total carboxylic acid concentration. Detection part of the examined system consists of ion-selective electrodes (ISEs) with polymer membranes of different compositions. First electrode is based on Zr(IV)-tetraphenylporphyrin

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico