Skip to Content
Merck

Skip To

1.08325

Toluene

for analysis EMSURE® ACS,ISO,Reag. Ph Eur

Synonym(s):

Toluol, Methylbenzene

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice

About This Item

Linear Formula:
C6H5CH3
CAS Number:
Molecular Weight:
92.14
UNSPSC Code:
12191501
NACRES:
NA.21
EC Index Number:
203-625-9
MDL number:
Beilstein/REAXYS Number:
635760
Assay:
≥99.9% (GC)
Grade:
ACS reagent
Bp:
110-111 °C (lit.)
Vapor pressure:
22 mmHg ( 20 °C), 26 mmHg ( 25 °C)
Pricing and availability is not currently available.
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


grade

ACS reagent

Quality Segment

agency

reag. ISO, reag. Ph. Eur.

vapor density

3.2 (vs air)

vapor pressure

22 mmHg ( 20 °C), 26 mmHg ( 25 °C)

product line

EMSURE®

assay

≥99.9% (GC)

form

liquid

autoignition temp.

997 °F

expl. lim.

7 %

dilution

(for analytical testing)

impurities

≤0.000002% As (Arsenic), ≤0.0002 meq/g Acidity, ≤0.0006 meq/g Alkalinity, ≤0.005% Benzene (GC), ≤0.03% Water, ≤0.5 ppm Chloride (Cl), ≤1 ppm Sulfate (SO4)

evapn. residue

≤0.0005%

color

clearAPHA: ≤10

refractive index

n/D 1.496 (lit.)

kinematic viscosity

0.7 cSt(20 °C)

bp

110-111 °C (lit.)

mp

-93 °C (lit.)

transition temp

flash point 4 °C

solubility

0.52 g/L

density

0.865 g/mL at 25 °C (lit.)

SMILES string

Cc1ccccc1

cation traces

Ag: ≤0.000002%, Al: ≤0.00005%, Au: ≤0.00001%, B: ≤0.000002%, Ba: ≤0.00001%, Be: ≤0.000002%, Bi: ≤0.00001%, Ca: ≤0.00005%, Cd: ≤0.000005%, Co: ≤0.000002%, Cr: ≤0.000002%, Cu: ≤0.000002%, Fe: ≤0.00001%, In: ≤0.000002%, Li: ≤0.000002%, Mg: ≤0.00001%, Mn: ≤0.000002%, Mo: ≤0.000005%, Ni: ≤0.000002%, Pb: ≤0.00001%, Pt: ≤0.000002%, Sb: ≤0.000002%, Sn: ≤0.00001%, Ti: ≤0.000005%, Tl: ≤0.000005%, V: ≤0.000005%, Zn: ≤0.00001%, Zr: ≤0.000002%

storage temp.

2-30°C

InChI

1S/C7H8/c1-7-5-3-2-4-6-7/h2-6H,1H3

InChI key

YXFVVABEGXRONW-UHFFFAOYSA-N

General description

EMSURE grade solvents are suitable for a broad spectrum of classical lab applications, and are frequently used in regulated and highly demanding lab applications. EMSURE provides worldwide best and most extensive product specifications. We declare our EMSURE range to be in compliance with the ACS, with the reagent part of the European Pharmacopoeia (Reag. Ph Eur) and also with the ISO standards.

Application


  • Toluene Detection in Biological Samples Using SPME-GC-MS.: This research presents a method for detecting toluene in biological samples using solid-phase microextraction combined with gas chromatography-mass spectrometry (SPME-GC-MS). The method provides high sensitivity and accuracy, making it suitable for biological monitoring of toluene exposure (Suh et al., 2015).

  • Adsorption Characteristics of Toluene on Metal-Organic Frameworks.: This paper explores the adsorption characteristics of toluene on various metal-organic frameworks (MOFs). The study identifies the most efficient MOFs for toluene adsorption, offering insights for industrial applications in air purification (Zhang et al., 2019).

Other Notes

Discover EMSURE - to be more than sure!
Explore various lab safety accessories and equipment for safe handling of solvents to increase your safety level from the first usage.

Legal Information

EMSURE is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
107019TX0735108389
description

for analysis EMSURE® ACS,ISO,Reag. Ph Eur

description

for analysis EMPARTA® ACS

description

Meets ACS Specifications, Meets Reagent Specifications for testing USP/NF monographs GR ACS

description

for gas chromatography ECD and FID SupraSolv®

Quality Level

300

Quality Level

200

Quality Level

300

Quality Level

100

assay

≥99.9% (GC)

assay

≥99.5% (GC)

assay

≥99.5% (GC)

assay

≥99.8% (GC)

grade

ACS reagent

grade

ACS reagent

grade

-

grade

-

solubility

0.52 g/L

solubility

-

solubility

0.52 g/L

solubility

-

form

liquid

form

liquid

form

liquid

form

liquid

mp

-93 °C (lit.)

mp

-93 °C (lit.)

mp

-93 °C (lit.)

mp

-93 °C (lit.)


Still not finding the right product?

Explore all of our products under Toluene


signalword

Danger

Hazard Classifications

Aquatic Chronic 3 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 2 Inhalation - STOT SE 3

target_organs

Central nervous system

Storage Class

3 - Flammable liquids

flash_point_f

39.9 °F - closed cup

flash_point_c

4.4 °C - closed cup



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. What is this toluene intended for? Is there toluene, acetone and isopropyl alcohol without chlorine intended for determining organic chlorine in crude oil according to ASTM D4929 by titration?

    1 answer
    1. The product is a research grade solvent. It is not tested for Chlorine content, nor is it guaranteed to be suitable for use in ASTM D4929 testing.
      To seek a product tested for Chlorine content or for suitability for a given ASTM method, please search our website for products by name, then click the product number of interest to view the specification sheet.

      Helpful?

  3. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters