Saltar al contenido
MilliporeSigma
Todas las fotos(1)

Documentos clave

24633

Supelco

Bolsa de muestreo de gases Tedlar PLV® de 1 l con membranas de goma Thermogreen® LB-2

Push/Pull Lock Valve (PLV)

Sinónimos:

Bolsa de muestreo de gases Tedlar®

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización

Seleccione un Tamaño

10 EA
$169.00

$169.00


Disponible para envío el07 de abril de 2025Detalles


Solicitar un pedido a granel

Seleccione un Tamaño

Cambiar Vistas
10 EA
$169.00

About This Item

Código UNSPSC:
41104008

$169.00


Disponible para envío el07 de abril de 2025Detalles


Solicitar un pedido a granel

Materiales

Tedlar® PVDF film

Agency

suitable for ASTM® D5504 (Sulfur Compounds in Natural Gas and Fuels by GC)
suitable for EPA 18 (Gaseous Organic Compounds; VOCs by GC)
suitable for EPA 40,TO-3,TO-15 (Volatile Organic Compounds (VOCs))
suitable for EPA TO-12 (Non-Methane Organic Compounds (NMOC))
suitable for EPA TO-14A (Volatile Organic Compounds (VOCs) by GC/MS)
suitable for NIOSH 3704 (Perchloroethylene)

descripción

septum type: yes; Thermogreen® LB-2

envase

pkg of 10 bags

técnicas

whole air sampling: suitable

An × L

7 in. × 9 in.

volumen máximo

1 L

aplicaciones

air monitoring
environmental
industrial hygiene

compatibilidad

for use with Calibration mixes - gas phase standards/gas mixtures

¿Está buscando productos similares? Visita Guía de comparación de productos

Descripción general

En varios métodos de la EPA se recomienda Tedlar para el muestreo de los VOC y de compuestos de azufre. Nuestro Tedlar está fabricado con una película de Tedlar de 2 mil de alta calidad para una mayor inercia, impermeabilidad, integridad de las muestras y buenos datos de recuperación. Nuestra válvula de bloqueo a presión (PLV) y el proceso de sellado de juntas garantizan que estas bolsas son resistentes y prácticamente a prueba de fugas, incluso en las condiciones de muestreo y transporte más exigentes.

Aplicación

Las bolsas Tedlar pueden usarse para contener aire que contenga arsinos, durante la determinación de la estabilidad atmosférica de los arsinos.[1]

Información legal

ASTM is a registered trademark of American Society for Testing and Materials
Tedlar is a registered trademark of E. I. du Pont de Nemours and Company
Thermogreen is a registered trademark of Merck KGaA, Darmstadt, Germany

Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Si necesita más asistencia, póngase en contacto con Atención al cliente

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Atmospheric stability of arsines and the determination of their oxidative products in atmospheric aerosols (PM 10): evidence of the widespread phenomena of biovolatilization of arsenic.
Jakob R
Journal of Environmental Monitoring, 12 (2), 409-416 (2010)
A Enel et al.
Lab on a chip, 20(7), 1290-1297 (2020-03-12)
Digital microfluidics is known for fine manipulation of sub-millimeter samples, with applications from biological sample preparation to diagnostic testing. Unfortunately, until now, it has been only limited to liquid phases. In this paper, we present a new system based on
Alveolar sampling and fast kinetics of tetrachloroethene in man. I. Alveolar sampling.
Opdam JJ and Smolders F.
British Journal of Industrial Medicine, 43 (12), 814-824 (1986)

Contenido relacionado

El control del aire se utiliza para medir el nivel de contaminantes del aire en entornos medioambientales, industriales o de interior para evaluar la calidad del aire en función de los valores establecidos por las autoridades competentes.

Air monitoring is used to measure the level of air pollutants in environmental, industrial, or indoor settings to assess the air quality per standards established by health and regulatory agencies.

Questions

1–9 of 9 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. About TedlarGasSamplingBag(1L), do you have appropriate PVC tube (3/16" ID) or any kind of tube to connect the bag to sampling point? General one is very slightly wider than nozzle on it.

    1 answer
    1. The PVC laboratory tubing that has an (I.D.) of 3/16" is Product Z280364-1PAK. However, it must be noted that the polypropylene valve stem is 3/16" in outside diameter (O.D.) which means that the recommended tubing must have 1/4" (I.D.) which is Product Z280372-1PAK.

      Helpful?

  4. For 24633 product, what is the maximum temperature and pressure the bag can withstand? and is it in transparent form?

    1 answer
    1. Tedlar® films are rated for continuous use from -72°C to 107°C (-98°F to 225°F). This Tedlar® PVDF film is transparent. The Tedlar film has a tensile strength of 8000 psi while the recommended fill pressure is 17.7 psi. The maximum fill volume should be limited to 75 - 80 % to allow for pressure changes.

      Helpful?

  5. Is there any recommendation regarding how often the septum can be pierced with a needle for removal of gas, until the septum loses its integrity?

    1 answer
    1. The septum is located at the base flange of the valve with the bag film below. The septum does not come into contact with the sample. The septum allows repeated punctures with syringes without leakage. The number of times the fluoropolymer septum may be punctured before it loses its integrity had not been determined. A small guage needle should assure maximum life of the septum.

      Helpful?

  6. How full can I fill a Tedlar bag, Product 24633, Tedlar® Gas Sampling Bag?

    1 answer
    1. Flush the Tedlar bag several times with nitrogen prior to use. We recommend filling the bag to approximately 80% of capacity.

      Helpful?

  7. What is Tedlar, as used in the description of Product 24633, Tedlar® Gas Sampling Bag?

    1 answer
    1. Tedlar is a polyvinyl fluoride (PVF) film manufactured by DuPont that has excellent resistance to chemicals.

      Helpful?

  8. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  9. What size of tubing can I use with Product 24633, Tedlar® Gas Sampling Bag?

    1 answer
    1. The polypropylene valve stem is 3/16 inch outside diameter (o.d.) making it suitable for use with most 1/4 inch o.d. tubing.

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico