The column has fixed polypropylene end caps, polyethylene bed supports, and Luer-Lock inlet and outlet fittings. The column outlet and reservoir top are permanently attached, while the reservoir cap is threaded. For the 0.7 cm i.d., there is no flow adapter, and a funnel can be used to pack the column after removing the threaded reservoir cap.
C3669
Liquid chromatography columns
Luer Lock, Non-jacketed, bed volume 4 mL, I.D. × L 0.7 cm × 10 cm
Seleccione un Tamaño
$232.00
Disponibilidad
Disponible para envío el08 de enero de 2025Detalles
Seleccione un Tamaño
About This Item
$232.00
Disponibilidad
Disponible para envío el08 de enero de 2025Detalles
Productos recomendados
grade
for chromatography
technique(s)
LPLC: suitable
I.D. × L
0.7 cm × 10 cm
bed volume
4 mL
¿Está buscando productos similares? Visita Guía de comparación de productos
General description
A - Luer-Lock, Non Jacketed: Fixed polypropylene end caps, polyethylene bed supports, Luer-Lock inlet and outlet fittings.
B - Luer-Lock, Jacketed: Same as A (above), with a borosilicate glass jacket surrounding the column body for temperature control.
C - Open-ended: Fixed polypropylene ends (outside of tube only), without jacket or end fittings. Requires 2 flow adapters.
D - PTFE, non-jacketed: Threaded ends, removable PTFE fittings with shielded O-ring seals, 20 μm polyethylene bed supports, and 1/4-28 threaded tubing connections. Solvents contact only PTFE and borosilicate glass.
E - PTFE, jacketed: Same as D (above), with an acrylic jacket surrounding the column body for temperature control.
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
-
Can the top of this column be unscrewed for packing purposes? Also, do you have a detailed image of this column?
1 answer-
Helpful?
-
-
Questo tipo di colonna con codice C-3669 è compatibile con solventi organici come esano, diclorometano o acetato di etile?
1 answer-
This column has not been tested with these solvents. It will be damaged by dichloromethane and ethyl acetate. Hexane may cause swelling and leakage.
Helpful?
-