Saltar al contenido
MilliporeSigma

PHR1030

Supelco

DL-α-Tocopherol acetate

Pharmaceutical Secondary Standard; Certified Reference Material

Sinónimos:

DL-α-Tocopherol acetate, Vitamin E acetate, all-rac-α-Tocopheryl acetate

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización

Seleccione un Tamaño

500 MG
$85.60

$85.60


En stockDetalles


Solicitar un pedido a granel

Seleccione un Tamaño

Cambiar Vistas
500 MG
$85.60

About This Item

Fórmula empírica (notación de Hill):
C31H52O3
Número de CAS:
Peso molecular:
472.74
Beilstein/REAXYS Number:
97512
EC Number:
MDL number:
UNSPSC Code:
41116107
PubChem Substance ID:
NACRES:
NA.24

$85.60


En stockDetalles


Solicitar un pedido a granel

grade

certified reference material
pharmaceutical secondary standard

Quality Level

agency

traceable to Ph. Eur. T1600000
traceable to USP 1667701

API family

tocopherol

CofA

current certificate can be downloaded

technique(s)

HPLC: suitable
gas chromatography (GC): suitable

density

0.96 g/mL at 20 °C (lit.)

application(s)

pharmaceutical (small molecule)

format

neat

storage temp.

2-8°C

SMILES string

CC(C)CCC[C@@H](C)CCC[C@@H](C)CCC[C@]1(C)CCc2c(C)c(OC(C)=O)c(C)c(C)c2O1

InChI

1S/C31H52O3/c1-21(2)13-10-14-22(3)15-11-16-23(4)17-12-19-31(9)20-18-28-26(7)29(33-27(8)32)24(5)25(6)30(28)34-31/h21-23H,10-20H2,1-9H3/t22-,23-,31-/m1/s1

InChI key

ZAKOWWREFLAJOT-CEFNRUSXSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

General description

Certified pharmaceutical secondary standards for application in quality control provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to in-house working standards.

Application

α-Tocopheryl acetate may be used as an internal standard in the determination of α-tocopherol in human serum or plasma samples using high performance chromatography (HPLC).[1][2] It may also be used pharmaceutical reference standard for the quantification of the analyte in pharmaceutical formulations using spectrophotometric technique.[3]
These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.

Analysis Note

These secondary standards offer multi-traceability to the USP, EP (PhEur) and BP primary standards, where they are available.

Other Notes

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Footnote

To see an example of a Certificate of Analysis for this material enter LRAC1696 in the slot below. This is an example certificate only and may not be the lot that you receive.

Recommended products

Find a digital Reference Material for this product available on our online platform ChemisTwin® for NMR. You can use this digital equivalent on ChemisTwin® for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here and start your free trial.

Storage Class

10 - Combustible liquids

wgk_germany

WGK 1

flash_point_f

No data available

flash_point_c

No data available


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Si necesita más asistencia, póngase en contacto con Atención al cliente

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

A routine method for the simultaneous measurement of retinol, ?-tocopherol and five carotenoids in human plasma by reverse phase HPLC
Talwar D, et al.
Clinica Chimica Acta; International Journal of Clinical Chemistry, 270, 85-100 (1998)
Simultaneous determination of retinol and alpha-tocopherol in serum or plasma by liquid chromatography
Catignani LG and Bieri GJ
Clinical Chemistry, 29, 708-712 (1983)
Flow injection spectrophotometric determination of vitamin E in pharmaceuticals, milk powder and blood serum using potassium ferricyanide-Fe (III) detection system
Jadoon S, et al.
Chinese Chemical Letters = Zhongguo Hua Xue Kuai Bao, 21(6), 712-715 (2010)
Po-Hsien Huang et al.
Science signaling, 6(267), ra19-ra19 (2013-03-21)
Vitamin E is a fat-soluble vitamin with antioxidant properties. Tocopherols are the predominant form of vitamin E found in the diet and in supplements and have garnered interest for their potential cancer therapeutic and preventive effects, such as the dephosphorylation
Katharina M Espe et al.
Clinical journal of the American Society of Nephrology : CJASN, 8(3), 452-458 (2013-01-22)
Trials with the antioxidant vitamin E have failed to show benefit in the general population. Considering the different causes of death in ESRD, this study investigated the association between plasma concentrations of α-tocopherol and specific clinical outcomes in diabetic hemodialysis

Questions

1–3 of 3 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. 製品規格をおしえていただけますか。 純度について情報がほしいです。

    1 answer
    1. Hello. You can view an example Certificate of Analysis for this product by entering the example lot number LRAC1696. Though this is an example certificate only and may not be the lot that you receive, it includes an example of a purity value.

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico