MPTMAG-49K
MILLIPLEX® Mouse Pituitary Magnetic Bead Panel - Endocrine Multiplex Assay
The analytes available for this multiplex kit are: ACTH, BDNF, FSH, GH, Prolactin, TSH, LH.
About This Item
Productos recomendados
Quality Level
species reactivity
mouse
manufacturer/tradename
Milliplex®
assay range
accuracy: 96-101%
standard curve range: 12.2-50,000 pg/mL
(TSH)
standard curve range: 122-500,000 pg/mL
(Prolactin)
standard curve range: 2.4-10,000 pg/mL
(ACTH)
standard curve range: 2.4-10,000 pg/mL
(BDNF)
standard curve range: 24.4-100,000 pg/mL
(FSH)
standard curve range: 4.9-20,000 pg/mL
(GH)
standard curve range: 4.9-20,000 pg/mL
(LH)
inter-assay cv: <20%
intra-assay cv: <15%
technique(s)
multiplexing: suitable
detection method
fluorometric (Luminex xMAP)
shipped in
wet ice
General description
MILLIPLEX® Mouse Pituitary Panel is a 7-plex kit to be used for the simultaneous quantification of any or all of the following analytes in mouse serum, plasma, and tissue culture samples: ACTH, BDNF, FSH, GH, Prolactin, TSH and LH. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Endocrine
Application
- Analytes: ACTH, BDNF, FSH, GH, LH, Prolactin, TSH
- Recommended Sample Type: Mouse serum, plasma, cell/tissue culture supernatants or lysates
- Recommended Sample Dilution: 10 μL per well of undiluted serum or plasma; cell/tissue culture samples may require dilution in an appropriate control medium.
- Assay Run Time: For greater sensitivity an overnight incubation is recommended, (16-18 hours) at 2-8°C. Alternatively, incubate for 2 hours at room temperature (20-25°C).
- Research Category: Endocrine
- Research Subcategory: Metabolism
Features and Benefits
Other Notes
Legal Information
signalword
Danger
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 3
target_organs
Respiratory system
Storage Class
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Contenido relacionado
UnEnhance research with MILLIPLEX® multiplexing tips, industry guidance, and one-day assays for limited lab time.
MILLIPLEX® toxicity assays advance liver, kidney, and genotoxicity research by simultaneously measuring multiple toxicity biomarkers.
Multiplex immunoassays save time and sample volume in metabolic syndrome research, providing comprehensive insights into related conditions.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico