Saltar al contenido
MilliporeSigma
Todas las fotos(1)

Documentos clave

ABF1207-AF488

Sigma-Aldrich

Anti-phospho-Syk (Tyr323) Antibody, Alexa Fluor 488 Conjugate

from rabbit, ALEXA FLUOR 488

Sinónimos:

Tyrosine-protein kinase Syk, p72-Syk, p72Syk, Spleen tyrosine kinase

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización

Seleccione un Tamaño

100 μL
$553.00

$553.00


Check Cart for Availability

Solicitar un pedido a granel

Seleccione un Tamaño

Cambiar Vistas
100 μL
$553.00

About This Item

Código UNSPSC:
12352203
eCl@ss:
32160702

$553.00


Check Cart for Availability

Solicitar un pedido a granel

origen biológico

rabbit

Nivel de calidad

conjugado

ALEXA FLUOR 488

forma del anticuerpo

affinity isolated antibody

tipo de anticuerpo

primary antibodies

clon

polyclonal

reactividad de especies

human

técnicas

immunocytochemistry: suitable

Nº de acceso NCBI

Nº de acceso UniProt

Condiciones de envío

wet ice

modificación del objetivo postraduccional

phosphorylation (pTyr323)

Descripción general

Tyrosine-protein kinase Syk (EC 2.7.10.2; UniProt P43405; also known as p72-Syk, p72Syk, Spleen tyrosine kinase) is encoded by the SYK gene (Gene ID 6850) in human. Spleen tyrosine kinase (Syk) is a non-receptor tyrosine kinase highly expressed by haematopoietic cells. Syk plays a crucial role not only in adaptive immune receptor signalling, but also in cellular adhesion, innate immune recognition, osteoclast maturation, platelet activation and vascular development. Syk adopts an autoinhibited conformation in its inactive state and is activated upon binding immunoreceptor tyrosine-based activation motifs (ITAMs) and phosphorylation of tyrosine residues in the two linker regions (a.a. 108-160 and 260-370) between SH1 (a.a. 15-107) and SH2 (a.a. 168-259), and between SH2 and the kinase domain (a.a. 371-631). Initial ITAM binding triggers rapid activation of Syk, whereas subsequent phosphorylation leads to prolonged activation. In additon, Syk can phosphorylate ITAMs and autophosphorylate its own link region tyrosines, providing a positive feedback loop following initial ITAM-mediated Syk activation. Syk also mediates signalling of receptors that do not contain an ITAM, including integrins and C-type lectins, via interaction with ITAM-containing adaptors, such as DAP12 (TYROBP) and the FcR gamma-chain (FcRgamma).

Especificidad

Target phosphotyrosine residue coresponds to pTyr323 of human Syk spliced isoform 1 and pTyr300 of human Syk spliced isoform 2. Sequence surrounding the target tyrosine is not well conserved in mouse and rat Syk.

Inmunógeno

Epitope: domain of:
KLH-conjugated linear peptide corresponding to a sequence surrounding phosphorylated Tyr323 of human Syk.

Aplicación

Detect Syk phosphorylated on tyrosine 323 using this rabbit polyclonal Anti-phospho-Syk (Tyr323), Alexa Fluor 488 Conjugate, Cat. No. ABF1207-AF488, validated for use in Immunocytochemistry.
Research Category
Signaling
The unconjugated antibody (Cat. No. ABF1207) is also available for Western blotting application.

Calidad

Evaluated by Immunocytochemistry in Jurkat cells.

Immunocytochemistry Analysis: A 1:100 dilution of this antibody detected Syk Tyr323 phosphorylation induction in hydrogen peroxide-treated Jurkat cells.

Descripción de destino

~72/69 kDa observed. 72.07/69.51 kDa (human Syk isoform 1/2) calculated.

Forma física

Affinity purified.
Purified rabbit polyclonal antibody Alexa Fluor 488 conjugate in PBS with 1.5% BSA and 0.05% sodium azide.

Almacenamiento y estabilidad

Stable for 1 year at 2-8°C from date of receipt.

Otras notas

Concentration: Please refer to lot specific datasheet.

Información legal

ALEXA FLUOR is a trademark of Life Technologies

Cláusula de descargo de responsabilidad

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

¿No encuentra el producto adecuado?  

Pruebe nuestro Herramienta de selección de productos.

Código de clase de almacenamiento

12 - Non Combustible Liquids

Clase de riesgo para el agua (WGK)

WGK 2

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Questions

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico