The elution order for this product is not reported in the Certificate of Analysis. However, as per the principle of Mass Spectrometry, the separation is based on the mass/charge ratio of the species. The species with less mass/charge ratio elute first and those with the highest mass/charge ratio elute last. Thus, the elution order will be Li, Mg, NH4, Ca, Na, Mn, K, Sr, and Ba.
Seleccione un Tamaño
| A ustedes/SKU | Disponibilidad | Precio |
|---|---|---|
100 mL | Comprobar disponibilidad del carrito | $258.00 $193.50 |
Acerca de este artículo
$193.50
Precio de catálogo$258.00Ahorre 25 %product line
Certipur®
Quality Segment
composition
NH<SUB>4</SUB>, Ba, Ca, K, Li, Na, Mg, Mn, Sr, 100 mg/L (in 1mM HNO<SUB>3</SUB>)
technique(s)
ion chromatography: suitable
application(s)
environmental
food and beverages
format
multi-component solution
storage temp.
15-25°C
General description
Analysis Note
Accuracy of the method: NH4, Ba, Ca, K, Li, Mg, Mn, Na, Sr; 5%
NH₄ (Ammonium): 95.0 - 105.0 mg/l
Ba (barium): 95.0 - 105.0 mg/l
Ca (calcium): 95.0 - 105.0 mg/l
K (potassium): 95.0 - 105.0 mg/l
Li (Lithium): 95.0 - 105.0 mg/l
Mg (Magnesium): 95.0 - 105.0 mg/l
Mn (Manganese): 95.0 - 105.0 mg/l
Na (sodium): 95.0 - 105.0 mg/l
Sr (Strontium): 95.0 - 105.0 mg/l
Other Notes
Legal Information
1 of 1
Este artículo | |||
|---|---|---|---|
| technique(s) ion chromatography: suitable | technique(s) ICP: suitable | technique(s) ICP: suitable | technique(s) ICP: suitable |
| application(s) environmental | application(s) industrial qc | application(s) industrial qc | application(s) industrial qc |
| format multi-component solution | format single component solution | format single component solution | format single component solution |
| Quality Level 100 | Quality Level 300 | Quality Level 300 | Quality Level 300 |
| storage temp. 15-25°C | storage temp. 15-25°C | storage temp. 15-25°C | storage temp. 15-25°C |
| product line Certipur® | product line Certipur® | product line Certipur® | product line Certipur® |
Clase de almacenamiento
12 - Non Combustible Liquids
wgk
nwg
flash_point_f
Not applicable
flash_point_c
Not applicable
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
-
Pl provide the elution order with retention time for each cation.
1 answer-
Helpful?
-