Saltar al contenido
MilliporeSigma

Saltar a

1.00313

Hydrochloric acid

32%, EMPLURA®

Sinónimos:

Cloruro de hidrógeno solution

Iniciar sesión para ver los precios por organización y contrato.

Seleccione un Tamaño

Cambiar Vistas
A ustedes/SKUDisponibilidadPrecio
2.5 L
Comprobar disponibilidad del carrito
$85.60
25 L
Comprobar disponibilidad del carrito
$350.00
180 L
Comprobar disponibilidad del carrito
$1,890.00

Acerca de este artículo

Fórmula empírica (notación de Hill):
HCl
Número CAS:
Peso molecular:
36.46
UNSPSC Code:
12352301
NACRES:
NA.21
MDL number:
Assay:
≥32% (alkalimetric)
Form:
liquid

$85.60


Comprobar disponibilidad del carrito
Packaging: Glass bottle

Solicite una orden a granel
Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle


Nombre del producto

Ácido clorhídrico solution, 32% EMPLURA®

vapor pressure

21.3 hPa ( 20 °C)

Quality Segment

product line

EMPLURA®

assay

≥32% (alkalimetric)

form

liquid

impurities

≤0.0001% As (Arsenic), ≤0.0001% Free chlorine (Cl), ≤0.0001% Heavy metals (as Pb), ≤0.0002% Fe (Iron), ≤0.0005% Sulfate (SO4), ≤0.001% Sulfite (SO?)

pH

<1 (20 °C in H2O)

mp

-50 °C

density

1.16 g/cm3 at 20 °C

storage temp.

15-25°C

SMILES string

Cl

InChI

1S/ClH/h1H

InChI key

VEXZGXHMUGYJMC-UHFFFAOYSA-N

Application


  • Research on the Synthesis of Zinc-Ammonium Phosphate Using Galvanic Waste Sludge as a Source of Zinc: This study explores a novel approach using hydrochloric acid solution in the synthesis process aimed at valorizing waste materials. The article demonstrates a chemical strategy that enhances resource recovery, significantly contributing to waste minimization in industrial practices (Morgovan et al., 2024).

  • Contactless conductivity sensor employing moist paper as absorbent for in-situ detection of generated carbon dioxide gas: The study integrates hydrochloric acid solutions in the development of a novel, cost-effective contactless conductivity sensor. This sensor uses a simple paper-based system for the in-situ monitoring of gases, providing a significant tool in environmental monitoring and analysis (Nacapricha et al., 2020).


Analysis Note

Assay (alkalimetric): ≥ 32 %
Identity: passes test
Bromide, Iodide (Br,I): passes test
Free chlorine (Cl): ≤ 0.0001 %
Sulfate (SO₄): ≤ 0.0005 %
Sulfite (SO₃): ≤ 0.001 %
Heavy metals (as Pb): ≤ 0.0001 %
As (Arsenic): ≤ 0.0001 %
Fe (Iron): ≤ 0.0002 %
Residual solvents (ICH Q3C): ...excluded by production process
Evaporation residue: ≤ 0,01
Expiry date : see product label

Legal Information

EMPLURA is a registered trademark of Merck KGaA, Darmstadt, Germany

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 1

Este artículo
1.003181.003191.00316
assay

≥32% (alkalimetric)

assay

30%

assay

≥32.0% (alkalimetric)

assay

≥25.0% (alkalimetric)

Quality Level

200

Quality Level

100

Quality Level

300

Quality Level

300

form

liquid

form

liquid

form

liquid

form

liquid

storage temp.

15-25°C

storage temp.

15-25°C

storage temp.

15-25°C

storage temp.

2-30°C

pH

<1 (20 °C in H2O)

pH

<1 (20 °C, 300 g/L in H2O)

pH

<1 (20 °C in H2O)

pH

<1 (20 °C in H2O)

impurities

≤0.0001% As (Arsenic), ≤0.0001% Heavy metals (as Pb), ≤0.0005% Sulfate (SO4), ≤0.0001% Free chlorine (Cl), ≤0.001% Sulfite (SO?), ≤0.0002% Fe (Iron)

impurities

-

impurities

≤0.01 ppm As (Arsenic), ≤0.01 ppm Cd (Cadmium), ≤0.01 ppm Co (Cobalt), ≤0.01 ppm Hg (Mercury), ≤0.01 ppm Li (Lithium), ≤0.01 ppm Mn (Manganese), ≤0.01 ppm Mo (Molybdenum), ≤0.01 ppm Pb (Lead), ≤0.01 ppm Sr (Strontium), ≤0.01 ppm V (Vanadium), ≤0.02 ppm Ba (Barium), ≤0.02 ppm Be (Beryllium), ≤0.02 ppm Bi (Bismuth), ≤0.02 ppm Cr (Chromium), ≤0.02 ppm Cu (Copper), ≤0.02 ppm Ge (Germanium), ≤0.02 ppm Ni (Nickel), ≤0.02 ppm Ti (Titanium), ≤0.02 ppm Tl (Thallium), ≤0.02 ppm Zr (Zirconium), ≤0.05 ppm Ag (Silver), ≤0.05 ppm Al (Aluminium), ≤0.05 ppm Au (Gold), ≤0.05 ppm Ga (Gallium), ≤0.05 ppm In (Indium), ≤0.05 ppm Mg (Magnesium), ≤0.05 ppm Zn (Zinc), ≤0.10 ppm Fe (Iron), ≤0.10 ppm K (Potassium), ≤0.10 ppm Pt (Platinum), ≤0.2 ppm Ca (Calcium), ≤0.2 ppm Na (Sodium), ≤0.5 ppm Free chlorine (Cl), ≤0.5 ppm Phosphate (PO4), ≤1 ppm NH? (Ammonium), ≤1 ppm Sulfate (SO4), ≤1 ppm Sulfite (SO3), ≤50 ppm Bromide (Br)

impurities

≤0.01 ppm As (Arsenic), ≤0.010 ppm Cd (Cadmium), ≤0.010 ppm Co (Cobalt), ≤0.010 ppm Li (Lithium), ≤0.010 ppm Mn (Manganese), ≤0.010 ppm Sr (Strontium), ≤0.010 ppm V (Vanadium), ≤0.020 ppm Ba (Barium), ≤0.020 ppm Be (Beryllium), ≤0.020 ppm Cr (Chromium), ≤0.020 ppm Cu (Copper), ≤0.020 ppm Mo (Molybdenum), ≤0.020 ppm Ni (Nickel), ≤0.020 ppm Pb (Lead), ≤0.050 ppm Al (Aluminium), ≤0.050 ppm Ge (Germanium), ≤0.050 ppm Tl (Thallium), ≤0.050 ppm Zn (Zinc), ≤0.100 ppm Bi (Bismuth), ≤0.100 ppm K (Potassium), ≤0.100 ppm Mg (Magnesium), ≤0.100 ppm Ti (Titanium), ≤0.100 ppm Zr (Zirconium), ≤0.200 ppm Fe (Iron), ≤0.5 ppm Free chlorine (Cl), ≤0.500 ppm Ca (Calcium), ≤0.500 ppm Na (Sodium), ≤1 ppm NH4 (Ammonium), ≤1 ppm Sulfate (SO4), ≤1 ppm Sulfite (SO3), ≤50 ppm Bromide (Br)


Still not finding the right product?

Explore all of our products under Ácido clorhídrico solution


pictograms

CorrosionExclamation mark

signalword

Danger

Hazard Classifications

Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1B - STOT SE 3

target_organs

Respiratory system

wgk

WGK 1

flash_point_f

Not applicable

flash_point_c

Not applicable

Clase de almacenamiento

8B - Non-combustible corrosive hazardous materials



Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos



Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters