Saltar al contenido
MilliporeSigma

357243

Sigma-Aldrich

Tantalum

foil, thickness 0.05 mm, ≥99.9% trace metals basis

Sinónimos:

Ta

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula empírica (notación de Hill):
Ta
Número de CAS:
Peso molecular:
180.95
Número CE:
Número MDL:
Código UNSPSC:
12141741
ID de la sustancia en PubChem:
NACRES:
NA.23

presión de vapor

<0.01 mmHg ( 537.2 °C)

Nivel de calidad

Ensayo

≥99.9% trace metals basis

Formulario

foil

temp. de autoignición

572 °F

resistividad

13.5 μΩ-cm, 20°C

grosor

0.05 mm

bp

5425 °C (lit.)

mp

2996 °C (lit.)

densidad

16.69 g/cm3 (lit.)

cadena SMILES

[Ta]

InChI

1S/Ta

Clave InChI

GUVRBAGPIYLISA-UHFFFAOYSA-N

Descripción general

The structure of tantalum is body centered cubic (BCC) metal. It is a refractory metal; stable up to very high temperatures. Tantalum is ductile at room temperature and moderately ductile at cryogenic temperatures. Compton profile of highly pure thin elemental foil of tantalum was investigated using IGP type coaxial photon detector.1

Aplicación

0.05mm thick tantalum foil was filled with 12C or 13C powder to act as carbon source emitting low energy carbon atoms.

Cantidad

  • 100×100 mm (approximately 8.4 g)
  • 150×150 mm (approximately 18.9 g)

Código de clase de almacenamiento

11 - Combustible Solids

Clase de riesgo para el agua (WGK)

nwg

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable

Equipo de protección personal

Eyeshields, Gloves, type N95 (US)


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

A simple and clean source of low energy atomic carbon
Krasnokutski SA and Huisken F
Applied Physics Letters, 105 (2014)
The Morphology of Tensile Failure in Tantalum
Boyce BL, et al.
Metallurgical and Materials Transactions A: Physical Metallurgy and Materials Science, 44(10), 4567-4580 (2013)
Scott M Sporer et al.
Clinical orthopaedics and related research, 470(11), 3156-3163 (2012-09-25)
Stabilization of a pelvic discontinuity with a posterior column plate with or without an associated acetabular cage sometimes results in persistent micromotion across the discontinuity with late fatigue failure and component loosening. Acetabular distraction offers an alternative technique for reconstruction
Stuart A Callary et al.
Clinical orthopaedics and related research, 471(7), 2238-2244 (2013-01-22)
One cross-linked polyethylene (XLPE) liner is manufactured using a lower dose of radiation, 5 Mrad, which may result in less cross-linking. The reported in vivo wear rate of this XLPE liner in patients undergoing THA has varied, and has included
Thomas Larzon et al.
Vascular, 21(2), 87-91 (2013-03-20)
Control of back bleeding from the hypogastric artery into the aneurysm after endovascular aneurysm repair (EVAR) of a ruptured aorto-iliac aneurysm may be necessary in order to avoid a type II endoleak. It is an emergency situation and selective catheterization

Artículos

Combinatorial Materials Science identifies breakthrough materials through systematic exploration, aiding material discovery.

Biomedical implants are essentially foreign substances within the human body that must survive many years’ exposure to demanding mechanical and physiological conditions. Despite these challenges, metal implants have been widely used to substitute for or rebuild hard tissues such as bones and teeth.

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico