Saltar al contenido
MilliporeSigma

112437

Sigma-Aldrich

4-Ethylpyridine

98%

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula empírica (notación de Hill):
C7H9N
Número de CAS:
Peso molecular:
107.15
Beilstein/REAXYS Number:
106481
EC Number:
MDL number:
UNSPSC Code:
12352100
PubChem Substance ID:
NACRES:
NA.22

Quality Level

assay

98%

refractive index

n20/D 1.501 (lit.)

bp

168 °C (lit.)

density

0.942 g/mL at 25 °C (lit.)

SMILES string

CCc1ccncc1

InChI

1S/C7H9N/c1-2-7-3-5-8-6-4-7/h3-6H,2H2,1H3

InChI key

VJXRKZJMGVSXPX-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

General description

4-Ethylpyridine undergoes metal-ligand interaction with Zn-porphyrin which can be studied by mass spectrometry.

Application

4-Ethylpyridine is used to study the influence of counter-anion concentration on analyte retention.

pictograms

FlameExclamation mark

signalword

Warning

Hazard Classifications

Eye Irrit. 2 - Flam. Liq. 3 - Skin Irrit. 2 - STOT SE 3

target_organs

Respiratory system

Storage Class

3 - Flammable liquids

wgk_germany

WGK 3

flash_point_f

122.0 °F - closed cup

flash_point_c

50 °C - closed cup

ppe

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Los clientes también vieron

R LoBrutto et al.
Journal of chromatography. A, 913(1-2), 189-196 (2001-05-18)
The influence of acid and salt concentration in the mobile phase on the retention of basic analytes has been studied. An increase in the retention of fully protonated analytes with increasing the concentration of inorganic additives was found. The addition
Monica Brivio et al.
Lab on a chip, 5(10), 1111-1122 (2005-09-22)
Two simple interfaces were designed and realized, enabling on-line coupling of microfluidics reactor chips to a nanoflow electrospray ionization (NESI) time-of-flight (TOF) mass spectrometer (MS). The interfaces are based on two different approaches: a monolithically integrated design, in which ionization
Slavko Klobčar et al.
Biomedical chromatography : BMC, 29(12), 1901-1906 (2015-05-27)
The isolation of four oxidative degradation products of atorvastatin using preparative high-performance liquid chromatography applying at least two chromatographic steps is known from the literature. In this paper it is shown that the same four impurities could be isolated from
Michael Wleklinski et al.
Physical chemistry chemical physics : PCCP, 17(28), 18364-18373 (2015-06-25)
Electrospray ionization of metal salt solutions followed by ambient heating transforms the resulting salt clusters into new species, primarily naked ionic metal clusters. The experiment is done by passing the clusters through a heated coiled loop outside the mass spectrometer
Alexandre Grand-Guillaume Perrenoud et al.
Journal of chromatography. A, 1360, 275-287 (2014-08-19)
Superficially porous particles (SPP), or core shell particles, which consist of a non-porous silica core surrounded by a thin shell of porous silica, have gained popularity as a solid support for chromatography over the last decade. In the present study

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico