Modification of a gas chromatography/atmospheric pressure chemical ionisation time-of-flight mass spectrometer as an alternative to automated atmospheric pressure solids analysis probe.

Rapid communications in mass spectrometry : RCM (2014-08-19)
Peter Stokes, David Parker, Jackie Mosely
ABSTRACT

The atmospheric pressure solids analysis probe (ASAP) has been successfully introduced into laboratories as a routine analytical tool but the technique is labour-intensive and is not easily automated. This paper describes the modifications made to an existing atmospheric pressure gas chromatography (APGC) system to enable the automated analysis of samples that would have otherwise been analysed by ASAP. Liquid samples were injected into a 1 m piece of fused silica guard column using a standard split/splitless gas chromatography (GC) inlet, oven and autosampler. A novel timing delay circuit was developed and integrated into the system to control acquisition start times and a bespoke heating block/calibrant delivery system was used to transport either the calibration or reference compound into the ionisation source. The modified system has allowed the successful analysis of those samples requiring ASAP to be carried out in a fully automated manner using APGc. The analysis is rapid and can be carried out in less than 2 min. The results obtained are directly comparable with those obtained by ASAP. A typical mass accuracy of better than 5 mm/z units was achieved, allowing the molecules to be identified based on their elemental formulae. An existing APGC system has been successfully modified and is suitable for the automatic analysis of samples normally analysed by ASAP. The APGC instrument incorporates the use of a novel reference compound and delivery system which allows accurate mass measurements to be performed. This and the other modifications described have allowed the technique to be incorporated into an existing suite of mass spectrometry-based experiments for use in the characterisation of organic molecules.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetonitrile, JIS 5000
Sigma-Aldrich
Acetonitrile
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for HPLC
Sigma-Aldrich
Acetonitrile, JIS special grade, ≥99.5%
Sigma-Aldrich
Caffeine, SAJ special grade, ≥98.5%
Sigma-Aldrich
Acetonitrile, ≥99.8%, JIS 300
Sigma-Aldrich
Dichloromethane, JIS special grade, ≥99.0%
Sigma-Aldrich
Acetonitrile, ≥99.8%, JIS 1000
Sigma-Aldrich
Formic acid, JIS special grade, ≥98.0%
Sigma-Aldrich
Benzophenone, SAJ first grade, ≥99.0%
Sigma-Aldrich
Dichloromethane, SAJ first grade, ≥99.0%
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%, poly-coated bottles
Supelco
Caffeine, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Caffeine Melting Point Standard, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Benzophenone, analytical standard
Supelco
Caffeine, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Supelco
Dichloromethane solution, contains 10 % (v/v) methanol
USP
Caffeine melting point standard, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetonitrile, SAJ first grade, ≥99.0%
Sigma-Aldrich
DL-Leucine, ≥99% (HPLC)
Sigma-Aldrich
Caffeine, meets USP testing specifications, anhydrous
Sigma-Aldrich
Caffeine, BioXtra
Sigma-Aldrich
Caffeine, powder, ReagentPlus®
Sigma-Aldrich
Caffeine, Sigma Reference Standard, vial of 250 mg
Sigma-Aldrich
Caffeine, anhydrous, 99%, FCC, FG
Sigma-Aldrich
Dichloromethane, suitable for HPLC, ≥99.9%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Caffeine, anhydrous, tested according to Ph. Eur.
Supelco
Dichloromethane, analytical standard
Sigma-Aldrich
Sodium formate, BioUltra, ≥99.0% (NT)
Supelco
Acetonitrile, analytical standard