Skip to Content
MilliporeSigma
  • Identification and quantification of phytochemicals in nutraceutical products from green tea by UHPLC-Orbitrap-MS.

Identification and quantification of phytochemicals in nutraceutical products from green tea by UHPLC-Orbitrap-MS.

Food chemistry (2014-12-04)
Noelia López-Gutiérrez, Roberto Romero-González, Patricia Plaza-Bolaños, José Luis Martínez Vidal, Antonia Garrido Frenich
ABSTRACT

A method has been developed and validated for the simultaneous detection and quantification of phytochemicals in nutraceutical products obtained from green tea. For that purpose, ultra-high performance liquid chromatography coupled to single-stage Orbitrap high resolution mass spectrometry (UHPLC-Orbitrap-MS) has been used. A database containing 37 compounds has been used for the detection and identification of the target compounds. The developed methodology was based on solid-liquid extraction, using a mixture of methanol:H2O (80:20, v/v, pH 4), followed by dilution (10 times) with a mixture of ammonium acetate:methanol (50:50, v/v). Chromatographic conditions were optimised and full scan accurate mass data acquisition using electrospray ionisation in positive and negative ion mode was used. Moreover, all-ion fragmentation mode was used to get information of fragment ions, and they were used for identification purposes. The developed method was validated, obtaining repeatability (intra-day) and inter-day precision values (expressed as relative standard deviation, RSD) lower than 16% and 20%, respectively. Lower limits were also evaluated and limits of detection (LODs) ranged from 1 to 50 μg L(-1), while limits of quantification (LOQs) ranged from 2 to 150 μg L(-1). Recovery was performed at five levels and it ranged from 70% to 109%. Finally, this method was used to evaluate the phytochemical content in 10 samples (tablets or capsules), showing concentrations of (+)-catechin, (-)-epicatechin, gallic acid, (-)-gallocatechin and quercetin-3-O-rutinoside, ranging from 258 (C6) to 10,729 (C6) mg kg(-1).

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Sodium dodecyl sulfate, ≥99.0% (GC), dust-free pellets
Sigma-Aldrich
Sodium dodecyl sulfate, ≥99.0%
Sigma-Aldrich
Acetic acid, 99.5-100.0%
Sigma-Aldrich
Acetic acid, JIS special grade, ≥99.7%
Sigma-Aldrich
Sodium dodecyl sulfate, SAJ special grade, ≥97.0%
Sigma-Aldrich
Acetic acid solution, 1 M, 1 N
Sigma-Aldrich
Acetic acid, SAJ first grade, ≥99.0%
Sigma-Aldrich
Methanol, JIS 300, ≥99.8%, for residue analysis
Sigma-Aldrich
Acetic acid, ≥99.7%
Sigma-Aldrich
Methanol, SAJ first grade, ≥99.5%
Sigma-Aldrich
Methanol, JIS special grade, ≥99.8%
Sigma-Aldrich
Acetic acid, ≥99.7%, suitable for amino acid analysis
Sigma-Aldrich
Acetic acid-12C2, 99.9 atom % 12C
Sigma-Aldrich
Methanol, SAJ special grade
Sigma-Aldrich
Methanol, suitable for HPLC
Supelco
(−)-Gallocatechin, analytical standard
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (w/v) ammonium formate, 5 % (v/v) water, 0.1 % (v/v) formic acid, suitable for HPLC
Supelco
Melting point standard 235-237°C, analytical standard
Sigma-Aldrich
Methanol, NMR reference standard
Chlorogenic acid, primary reference standard
Sigma-Aldrich
Quercetin, ≥95% (HPLC), solid
Supelco
Sodium dodecyl sulfate, dust-free pellets, suitable for electrophoresis, for molecular biology, ≥99.0% (GC)
Supelco
(−)-Epigallocatechin, analytical standard
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%, poly-coated bottles
Supelco
Genistein, analytical standard
Caffeine for system suitability, European Pharmacopoeia (EP) Reference Standard
Supelco
(−)-Gallocatechin gallate, analytical standard
Epigallocatechin, primary reference standard
Supelco
Apigenin, analytical standard
Supelco
Methanol, analytical standard