Skip to Content
MilliporeSigma
All Photos(3)

Key Documents

203610

Sigma-Aldrich

Lead(II) oxide

99.999% trace metals basis

Synonym(s):

Lead monoxide, Plumbous oxide

Sign Into View Organizational & Contract Pricing

Select a Size

10 G
$101.00
50 G
$404.00

$101.00


Available to ship onApril 28, 2025Details


Request a Bulk Order

Select a Size

Change View
10 G
$101.00
50 G
$404.00

About This Item

Linear Formula:
PbO
CAS Number:
Molecular Weight:
223.20
EC Number:
MDL number:
UNSPSC Code:
12352303
PubChem Substance ID:
NACRES:
NA.23

$101.00


Available to ship onApril 28, 2025Details


Request a Bulk Order

vapor pressure

10 mmHg ( 0 °C)

Quality Level

assay

99.999% trace metals basis

form

powder and chunks

reaction suitability

reagent type: catalyst
core: lead

mp

886 °C (lit.)

SMILES string

O=[PbH2]

InChI

1S/O.Pb

InChI key

YEXPOXQUZXUXJW-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

General description

Lead(II) oxide (PbO) is an industrially important metal oxide with strong absorption cross sections, high carrier mobilities, and conductivities. It is widely applied in the field of storage batteries, dielectrics, gas sensors, pigments, and paints.

Application

Lead(II) oxide can be used as a precursor to prepare:
  • Gamma ray radiation shielding glasses such as GeO2-PbO-Al2O3–CaO glasses.
  • Perovskite ceramic materials. For example, it can be used to synthesize lead magnesium niobate, widely applied in the field of electronic ceramics due to its high dielectric constant and voltage stability.

signalword

Danger

Hazard Classifications

Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Acute 1 - Aquatic Chronic 1 - Carc. 2 - Lact. - Repr. 1A - STOT RE 1

target_organs

Central nervous system,Kidney,Blood

Storage Class

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

dust mask type N95 (US), Eyeshields, Gloves, type P2 (EN 143) respirator cartridges


Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

E M Ibragimova et al.
Journal of nanoscience and nanotechnology, 12(11), 8818-8821 (2013-02-21)
Widely used SiO2-PbO glasses can be a good model for studying electron structure of insulator-metal interface with many Si-O-Pb bonds and eutectic Pb-Si mixture. Gamma-radiation of 60Co with an energy of -1.25 MeV generates efficiently electronic and hole structure defects
Xingwen Lu et al.
Water research, 47(3), 1353-1360 (2013-01-05)
This study quantified the effects of lead stabilization by blending lead-containing sludge into glass-ceramics through sintering with aluminum- and silica-rich precursors. Using lead oxide (PbO) to simulate lead-laden sludge under thermal conditions, the predominant PbAl(2)O(4) phase was found at temperatures
Ding-Quan Ng et al.
Environmental science & technology, 46(20), 11062-11069 (2012-09-11)
Addition of orthophosphate has been commonly employed to suppress lead levels in drinking water. Its detailed mechanism and time required for it to become effective, however, have not been fully elucidated. In this study, we investigated the mechanistic role of
P Ganasen et al.
Food science and technology international = Ciencia y tecnologia de los alimentos internacional, 17(4), 343-349 (2011-09-16)
Pidan (alkaline egg) has been consumed widely in oriental countries and lead, a toxic element, has been used traditionally to yield the desirable characteristics. For safety concerns, alternative cations can be used for the production of pidan with comparable properties
Jonas Baltrusaitis et al.
Environmental science & technology, 46(23), 12806-12813 (2012-10-13)
Heterogeneous chemistry of nitrogen dioxide with lead-containing particles is investigated to better understand lead metal mobilization in the environment. In particular, PbO particles, a model lead-containing compound due to its widespread presence as a component of lead paint and as

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service