  • Biomonitoring for Exposure Assessment to Styrene in the Fibreglass Reinforced Plastic Industry: Determinants and Interferents.

Biomonitoring for Exposure Assessment to Styrene in the Fibreglass Reinforced Plastic Industry: Determinants and Interferents.

The Annals of occupational hygiene (2015-07-17)
Rossana Claudia Bonanni, Maria Pia Gatto, Enrico Paci, Andrea Gordiani, Monica Gherardi, Giovanna Tranfo
摘要

Fifty-eight workers exposed to styrene were monitored in four fibreglass reinforced plastic industries of Central Italy. The aim of the study was to explore the factors that can influence the levels of styrene exposure biomarkers of the workers and the aspects that might interfere with the exposure assessment measures, such as the co-exposure to acetone. Personal monitoring of professional exposure to airborne styrene and acetone was carried out by Radiello samplers and GC/MS analysis. Biological monitoring was performed by the determination of urinary metabolites, mandelic (MA), and phenylglyoxylic (PGA) acids with HPLC/MS/MS and unmetabolized styrene in saliva and venous blood by HS/GC/MS. The median values of the four sites ranged between 24.1 to 94.0mg m(-3) and 7.3 to 331.1mg g(-1) creatinine for airborne styrene and MA + PGA, respectively. A good linear correlation was found between styrene in air and its urinary metabolites (r = 0.854). The median value for airborne styrene was found to exceed the (Threshold Limit Value - Time Weighted Average) of 85 mg m(-3) in one site for all the workers and in two if only moulders are considered. The multiple linear regression model showed that the determinants of urinary MA + PGA excretion were the type of process, workers' tasks, level of acetone co-exposure, and the use of respiratory protection devices. Data show that the simultaneous exposure to acetone modify the styrene metabolism with a reduction in the levels of (MA + PGA) excreted. A significant linear log-correlation was found between salivary levels of styrene and blood concentration (r = 0.746) sampled at the same t x time.

材料
產品編號
品牌
產品描述

radiello 小柱吸附剂, for sampling BTEX and VOCs (CS2 Desorption), matrix SS net (100 mesh, 5.8 mm diam.), activated with activated charcoal (30-50 mesh), pk of 20
radiello 三角支撑板, pk of 20
radiello 扩散体外壳, white, configured for general use, pk of 20
radiello 小柱吸附剂, for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISIL®, pk of 20
radiello 扩散体外壳, blue, configured for sampling light sensitive compounds, pk of 20
radiello 小柱吸附剂, for sampling Ammonia (NH3), matrix microporous PE impregnated with phosphoric acid, pk of 20
radiello 扩散体外壳, yellow, configured for reduced sampling rates, pk of 20
radiello 小柱吸附剂, for sampling BTEX and VOCs (thermal desorption), matrix SS net (3 x 8 μm, 4.8 mm diam.), Carbograph, pk of 20
Supelco
radiello 亚甲蓝校正标准样,用于 H2S(硫化氢), pkg of 100 mL
radiello 室外防护罩, pk of 10
radiello 条形码标签, pk of 198
radiello 竖直连接头, threaded for standard use, pk of 20
radiello BTEX/VOC Starter试剂盒,CS2解吸
Supelco
radiello BTEX 校正套装(热解吸)
radiello 过滤套装, pk of 20
radiello 空储存管, glass (with stopper), volume 2.8 mL, pk of 100
Supelco
radiello醛校准标准品, 50 μg/mL each component in acetonitrile, pkg of 10 mL
Supelco
radiello BTEX 校正套装(CS2 解吸)
radiello 夹, suspending Radiello triangular support plate, pk of 20
radiello 1,3-丁二烯起动包,热解吸, pkg of 1 kit (2 RAD141 adsorbing cartridges and barcode labels, 1 RAD1202 yellow diffusive body, 1 RAD121 triangular support plate, 1 instruction sheet)