跳轉至內容
Merck
  • Polydopamine-reinforced magnetization of zeolitic imidazolate framework ZIF-7 for magnetic solid-phase extraction of polycyclic aromatic hydrocarbons from the air-water environment.

Polydopamine-reinforced magnetization of zeolitic imidazolate framework ZIF-7 for magnetic solid-phase extraction of polycyclic aromatic hydrocarbons from the air-water environment.

Journal of chromatography. A (2016-05-29)
Suling Zhang, Weixuan Yao, Jianbo Ying, Hongting Zhao
摘要

Zeolitic imidazolate frameworks (ZIFs) consist of metal nodes connected to imidazolate linkers, having both the properties of metal-organic frameworks (MOFs) and inorganic zeolites, such as controllable pore sizes, high porosity and surface areas, as well as exceptional thermal and chemical stability, thereby making them a class of attractive materials for diverse analytical applications. In this study, we reported a facile magnetization process of ZIF-7 (zinc benzimidazolate) for simultaneous magnetic extraction of polycyclic aromatic hydrocarbons (PAHs) by simply mixing ZIF-7 and polydopamine (PDA)-coated Fe3O4 nanoparticles (PDA@Fe3O4) in solutions. Functional groups (-OH and -NH2), provided by PDA as a highly efficient molecular linker, could attract and anchor ZIF-7 through noncovalent adsorption and covalent cross-link interactions, thereby promoting the complete magnetization of ZIFs and enhancing their stability and reusability. The bridging ligand benzimidazolate, could be bonded with PAHs because of its high surface area, large pores, accessible coordinative unsaturated sites (π-complexation), and π-π stacking action. This ZIF-based magnetic solid-phase extraction (SPE), coupled with gas chromatography/tandem mass spectrometry (GC/MS), was further evaluated for analysis of PAHs from rainwater and air samples of particulate matter less than 2.5μm in diameter (PM2.5). The main effective parameters, including ionic strength, solution pH, extraction time, desorption solvent and desorption time, were investigated, respectively. Under optimized conditions, the developed method based on Fe3O4@PDA/ZIF-7 gave detection limits of 0.71-5.79ng/L, and quantification limits of 2.50-19.2ng/L for PAHs, respectively. The relative standard deviations for intra-day and inter-day analyses were in the range of 3.1-9.1% and 6.1-12.7%, respectively. The PAHs founded in PM2.5 were in the range of 0.40-6.79ng/m(3). Good recoveries (>82%) with low relative standard deviations (≤9.2%) were achieved. This method was demonstrated to be an accurate, convenient and sensitive pretreatment procedure for trace analysis of environmental water and air samples.

材料
產品編號
品牌
產品描述

Supelco
SPME 纤维组件二乙烯基苯/羧基/聚二甲基硅氧烷 (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
SPME 纤维组件二乙烯基苯/羧基/聚二甲基硅氧烷 (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
SPME 纤维组件二乙烯基苯/羧基/聚二甲基硅氧烷 (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPME 纤维组件二乙烯基苯/羧基/聚二甲基硅氧烷 (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
SPME 纤维组件二乙烯基苯/羧基/聚二甲基硅氧烷 (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
固相微萃取 StableFlex 萃取头组合套件, for use with manual holder
Supelco
Carbowax-聚乙二醇 (PEG) 固相微萃取萃取头, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
固相微萃取 StableFlex 萃取头组合套件, needle size 23 ga, for use with autosampler
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), fused silica fiber, df 65 μm(PDMS/DVB, for use with manual holder, needle size 23 ga
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, df 85 μm(PA, for use with manual holder, needle size 24 ga
Supelco
SPME 纤维组件二乙烯基苯/羧基/聚二甲基硅氧烷 (DVB/CAR/PDMS), for use with autosampler, needle size 23 ga, metal alloy fiber, fiber L 2 cm