跳轉至內容
Merck
  • Biological monitoring of low benzene exposure in Italian traffic policemen.

Biological monitoring of low benzene exposure in Italian traffic policemen.

Toxicology letters (2008-07-22)
Paola Manini, Giuseppe De Palma, Roberta Andreoli, Diana Poli, Marta Petyx, Massimo Corradi, Antonio Mutti, Pietro Apostoli
摘要

A comparative evaluation of urinary biomarkers was carried out to characterize benzene exposure in a group of 100 traffic policemen of the city of Parma (Italy). All subjects were monitored once, in two consecutive days characterized by similar climatic conditions but preceded by two windy days. Benzene ambient concentration measured by municipal air monitoring stations was 1 microg/m(3) (Day 1) and 2 microg/m3 (Day 2). Personal exposure to ambient concentrations of benzene, toluene, ethylbenzene and xylene (BTEX) was assessed by using Radiello((R)) passive-diffusive samplers in a subgroup of 24 workers. Benzene metabolites, t,t-muconic acid (t,t-MA) and S-phenylmercapturic acid (S-PMA) were determined by isotopic dilution liquid chromatography-tandem mass spectrometry on spot urine samples collected at the end of the shift. Urinary benzene (U-B) was determined by solid-phase microextraction gas chromatography-mass spectrometry. Airborne benzene concentration expressed as median [and interquartile range] was 6.07 [0.28-9.53] microg/m(3), as assessed by personal sampling. Urinary concentrations of biomarkers in the whole group were 41.8 [34.1-89.8] microg/g creatinine for t,t-MA, 0.67 [0.23-1.32] microg/g creatinine for S-PMA, and 0.16 [0.13-0.26] microg/l for U-B. Smokers eliminated significantly higher concentrations of unchanged BTEX and benzene metabolites than non-smokers (p < 0.05). When traffic policemen were distinguished into indoor (n=31) and outdoor workers, no significant differences were observed for either airborne benzene or urinary biomarkers. Significantly lower concentrations of S-PMA and U-B were determined in samples collected at Day 1 as compared to Day 2 (p < 0.0001 and p = 0.003, respectively) suggesting that these biomarkers are enough sensitive and specific to detect changes in airborne benzene concentration even at few microg/m(3).

材料
產品編號
品牌
產品描述

radiello 小柱吸附剂, for sampling BTEX and VOCs (CS2 Desorption), matrix SS net (100 mesh, 5.8 mm diam.), activated with activated charcoal (30-50 mesh), pk of 20
radiello 三角支撑板, pk of 20
radiello 扩散体外壳, white, configured for general use, pk of 20
radiello 小柱吸附剂, for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISIL®, pk of 20
radiello 小柱吸附剂, for sampling Ammonia (NH3), matrix microporous PE impregnated with phosphoric acid, pk of 20
radiello 扩散体外壳, blue, configured for sampling light sensitive compounds, pk of 20
radiello 扩散体外壳, yellow, configured for reduced sampling rates, pk of 20
radiello 小柱吸附剂, for sampling BTEX and VOCs (thermal desorption), matrix SS net (3 x 8 μm, 4.8 mm diam.), Carbograph, pk of 20
Supelco
radiello 亚甲蓝校正标准样,用于 H2S(硫化氢), pkg of 100 mL
radiello 室外防护罩, pk of 10
radiello 条形码标签, pk of 198
radiello 竖直连接头, threaded for standard use, pk of 20
radiello BTEX/VOC Starter试剂盒,CS2解吸
Supelco
radiello BTEX 校正套装(热解吸)
radiello 过滤套装, pk of 20
radiello 空储存管, glass (with stopper), volume 2.8 mL, pk of 100
Supelco
radiello醛校准标准品, 50 μg/mL each component in acetonitrile, pkg of 10 mL
Supelco
radiello BTEX 校正套装(CS2 解吸)
radiello 夹, suspending Radiello triangular support plate, pk of 20
radiello 1,3-丁二烯起动包,热解吸, pkg of 1 kit (2 RAD141 adsorbing cartridges and barcode labels, 1 RAD1202 yellow diffusive body, 1 RAD121 triangular support plate, 1 instruction sheet)