Skip to Content
Merck

NIOSH Method 7903: IC Analysis of Inorganic Acids after Collection/Desorption using ORBO-53

NIOSH Method 7903: IC Analysis of Inorganic Acids after Collection/Desorption using ORBO™-53 application for air monitoring, application for HPLC

Materials

related product

Product No.
Description
Pricing

ORBO 53 Activated Silica Gel (20/40) specially cleaned, 400/200 mg with Glass Fiber Filters

GFF,F,F separators, O.D. × L 7 mm × 100 mm, pkg of 50 ea

CONDITIONS

sample/matrix

1 ppm of each component

adsorbent tube

ORBO-53 (20265)

column

Dionex S2 Fast Run Anion, 25 cm × 3 mm I.D.

mobile phase

3 mM sodium bicarbonate; 2.4 mM sodium carbonate

flow rate

3 mL/min

detector

conductivity (10μSiemans/ cm)

Description

Legal Information

ORBO is a trademark of Sigma-Aldrich Co. LLC