The protocol is published in the product datasheet, available in the 'DOCUMENTATION' section of this page, under the 'Mor Documents' tab. Please see the link below to review:
https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/271/475/mini26bul.pdf
Select a Size
About This Item
Skip To
packaging
pkg of 1 kit
manufacturer/tradename
Distributed for Phanos Technologies
storage condition
protect from light
technique(s)
flow cytometry: suitable
fluorescence
λex 551 nm; λem 567 nm (PKH26 dye)
application(s)
cell analysis
detection
detection method
fluorometric
shipped in
ambient
storage temp.
room temp
Quality Level
1 of 4
This Item | |||
|---|---|---|---|
| technique(s) flow cytometry: suitable | technique(s) - | technique(s) flow cytometry: suitable | technique(s) - |
| packaging pkg of 1 kit | packaging pkg of 1 kit | packaging pkg of 1 kit | packaging - |
| manufacturer/tradename Distributed for Phanos Technologies | manufacturer/tradename Distributed for Phanos Technologies | manufacturer/tradename Distributed for Phanos Technologies | manufacturer/tradename - |
| storage condition protect from light | storage condition protect from light | storage condition protect from light | storage condition - |
| fluorescence λex 551 nm; λem 567 nm (PKH26 dye) | fluorescence λex 551 nm; λem 567 nm (PKH26 dye) | fluorescence λex 490 nm; λem 502 nm (PKH67 dye) | fluorescence - |
| application(s) cell analysis | application(s) - | application(s) cell analysis | application(s) - |
General description
Application
- labelling microglial, natural killer cells and preadipocytes
- tracking of viable transplanted adipose-derived stem cells
- in vitro proliferation studies of bone marrow stem cells
- general cell membrane labeling, including for in vitro cell labeling and long term in vivo cell tracking.
Other Notes
Legal Information
Kit Components Only
- Diluent C 10 mL
- PKH26 Cell Linker in ethanol .1 mL
signalword
Danger
hcodes
Hazard Classifications
Eye Irrit. 2 - Flam. Liq. 2
Storage Class
3 - Flammable liquids
flash_point_f
57.2 °F - closed cup
flash_point_c
14 °C - closed cup
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
-
MINI26-1KTの実験プロトコルを入手したいのですが、どこにありますか?
1 answer-
Helpful?
-
-
Is it possible to lable cells with PKH26 at 4oC?
1 answer-
The membrane dyes will remain stable during the monoclonal staining at 4 deg C; however, capping of the monoclonal antibodies is highly probable if the general cell membrane labeling is carried out at ambient temperature subsequent to antibody labeling. As additional information may be required to address the question completely, please navigate to the link https://www.sigmaaldrich.com/techservice, click on "Product Technical Inquiries" under the Products Section with all the information needed so that a member of the Technical Service team can reach out to assist further.
For more information, please refer to the product data-sheet below: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/271/475/mini26bul.pdf.
Helpful?
-
Active Filters
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service