Here are the troubleshooting steps for the dialysis set-up and nitrogen escape from the top lead seal:
1) Before starting the diafiltration, customers should run gas pressure directly to the stirred cell for 5-10 seconds with the selector valve in “gas” mode.
2) Petroleum jelly will likely be required to completely seal the top gasket of the stirred cell.
UFSC05001
Amicon® Stirred Cell 50mL
This Amicon stirred cell model provides high flow rates with solutions up to 10% macrosolute concentration. Capable of rapid concentration, or salt removal followed by concentration in the same unit.
Synonym(s):
Stirred Cell
About This Item
Recommended Products
material
316 stainless steel ring(s) (stir bar retaining)
316 stainless steel washer
Nylon connections (Luer on filtrate tubing)
Tygon® tubing (filtrate; E-3603)
polyacetal base
polyacetal support (for stir bar)
polyethylene tubing (pressure)
polysulfone body
polysulfone cap
polysulfone holder (for membrane)
polysulfone stir bar(s)
silicone O-ring
silicone gasket
Quality Level
product line
Amicon®
manufacturer/tradename
Amicon®
parameter
50 mL process volume
technique(s)
protein clean-up: suitable (desalting)
protein purification: suitable (concentration)
H
11.7 cm (4.6 in.)
filter diam.
44.5 mm
filtration area
13.4 cm2
shipped in
ambient
Application
Principle
Linkage
Legal Information
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
Articles
Amicon Stirred Cells concentrate and buffer-exchange macrosolutes efficiently with pressure-driven filtration.
Amicon Stirred Cells concentrate and buffer-exchange macrosolutes efficiently with pressure-driven filtration.
Amicon Stirred Cells concentrate and buffer-exchange macrosolutes efficiently with pressure-driven filtration.
Amicon Stirred Cells concentrate and buffer-exchange macrosolutes efficiently with pressure-driven filtration.
-
How can I troubleshoot the issue with ufsc05001 where, during the process of diafiltration to push liquid into the stirred cell, the liquid is added too fast and overflows?
1 answer-
Helpful?
-
-
Is the membrane holder for the Amicon Stirred Cell UFSC05001 sold as a replacement part?
1 answer-
No, the membrane holder component of the UFSC Amicon Stirred Cells is not sold separately.