Skip to Content
Merck
All Photos(1)

Key Documents

739553

Sigma-Aldrich

Poly(styrene-block-methyl methacrylate)

average Mn 32,000, block ratio of 2:1

Synonym(s):

PS-PMMA, block copolymer, Poly(b-methyl methacrylate-polystyrene), PS-block-PMMA, PS-PMMA

Sign Into View Organizational & Contract Pricing


About This Item

CAS Number:
UNSPSC Code:
12162002
Pricing and availability is not currently available.

form

solid

mol wt

average Mn 10,000 (PMMA)
average Mn 22,000 (polystyrene)
average Mn 32,000

transition temp

Tm 351-356 °C

Mw/Mn

<1.2

InChI

1S/C8H8.C5H8O2/c1-2-8-6-4-3-5-7-8;1-4(2)5(6)7-3/h2-7H,1H2;1H2,2-3H3

InChI key

ADFPJHOAARPYLP-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

General description

22 kDa PS; 10 kDa PMMA; m ~200; n ~100

Pictograms

Exclamation mark

Signal Word

Warning

Hazard Statements

Precautionary Statements

Hazard Classifications

Eye Irrit. 2

Storage Class Code

13 - Non Combustible Solids

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable


Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

F N K Kwong et al.
The Journal of bone and joint surgery. British volume, 88(1), 120-122 (2005-12-21)
The outcome of a cemented hip arthroplasty is partly dependent on the type of cement which is used. The production of an interface gap between the stem and the cement mantle as a result of shrinkage of the cement, may
S J Breusch et al.
Acta orthopaedica Scandinavica, 72(1), 29-35 (2001-05-01)
In a cadaver study, we prepared 29 paired human cadaver femora using 3 different broaches of identical geometry but different surface characteristics. In one group of 20 pairs, preparation with chipped-toothed broaches was compared to diamond-shaped broaches; in the other
M H Geiger et al.
Clinical orthopaedics and related research, (382)(382), 258-266 (2001-01-12)
This controlled study compared the strength and porosity of 48 polymethylmethacrylate cement-implant constructs prepared with open bowl versus vacuum mix technique. Forty-eight blast finished stainless steel rods of 13 mm diameter were implanted with centralizers into 17-mm inner diameter tubes
N Greene et al.
American journal of orthopedics (Belle Mead, N.J.), 27(3), 201-205 (1998-04-17)
In vitro studies of antibiotic elution from polymethylmethacrylate cement comparing Simplex (Howmedica, Rutherford, NJ) with Palacos brands (Richards, Memphis, TN) have shown variable results. This study compares the elution of tobramycin and vancomycin from Simplex and Palacos beads and spacers.
A D Puckett et al.
Critical reviews in biomedical engineering, 28(3 - 4), 457-461 (2000-12-07)
Poly(methylmethacrylate) (PMMA) bone cements have been used for the fixation of hip and knee implants since the early 1960s. Aseptic loosening, related to fracture of the PMMA, continues to be the primary mode of failure for these prostheses. Failed prostheses

Questions

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service