Yes, this product includes both the tube and fittings. The inlet and outlet fittings are 1/8' female NPT. There are also four interchangeable floats included.
Glass – Upper flow rate of 6 mL/min
Sapphire – Upper flow rate of 8 mL/min
Stainless Steel – Upper flow rate of 17 mL/min
Carboloy – Upper flow rate of 33 mL/min
Select a Size
| Size/SKU | Availability | Price |
|---|
About This Item
parameter
0-33 mL/min flow rate
General description
The rotameter is easy to mount. Alternatively, it can be installed on a tripod assembly (order tripod assembly separately). Available with or without needle valve.
Specifications:
- Max. Pressure: 200 psig (13.8 bar)
- Max. Temp.: 250 °F (121 °C)
- Connections: 1/8 in. female NPT (use connector to male NPT fittings to connect into gas delivery system)
Float Upper Flow Rates
0-33 mL/min. Rotameter
- Glass Float: 6 mL/min.
- Sapphire Float: 8 mL/min.
- Stainless Steel Float: 17 mL/min.
- Carboloy Float: 33 mL/min.
0-110 mL/min. Rotameter
- Glass Float: 19 mL/min.
- Sapphire Float: 30 mL/min.
- Stainless Steel Float: 61 mL/min.
- Carboloy Float: 110 mL/min.
0-246 mL/min. Rotameter
- Glass Float: 49 mL/min.
- Sapphire Float: 73 mL/min.
- Stainless Steel Float: 137 mL/min.
- Carboloy Float: 246 mL/min.
0-454 mL/min. Rotameter
- Glass Float: 92 mL/min.
- Sapphire Float: 140 mL/min.
- Stainless Steel Float: 264 mL/min.
- Carboloy Float: 454 mL/min.
Application
Disclaimer
1 of 1
This Item | |||
|---|---|---|---|
| parameter 0-33 mL/min flow rate | parameter 0-454 mL/min flow rate | parameter 0-454 mL/min flow rate | parameter 0-244 mL/min flow rate |
Still not finding the right product?
Explore all of our products under Supelco Rotameter
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
-
is this comes along with borosilicate tube and ss fittings
1 answer-
Helpful?
-
-
Is this calibrated for use with Nitrogen?
1 answer-
This product is calibrated with nitrogen.
Helpful?
-
-
Does the rotameter with SKU 23324, which is described as having connections of 1/8 in female NPT, mean that it is equipped with 1/8 in. female NPTs for both the inlet and outlet?
1 answer-
The rotameter with SKU 23324 is equipped with 1/8" female NPT fittings for both the inlet and outlet. Therefore, the fitting used should be a 1/8" Male NPT to connect to another component on the other side. An example of this type of fitting is available. The inlet and outlet fittings are made of black anodized aluminum.
Helpful?
-
-
Is rotameter 23324 compatible with sulfonic acid or methanesulfonic acid?
1 answer-
There are no compatibility data available for methanesulfonic acid or sulfonic acid with the rotameter 23324. As a result, using these untested chemicals with the rotameter in question will void any warranty.
Helpful?
-