Skip to Content
Merck

Skip To

901773

Silver/silver chloride (60/40) paste for screen printing

Synonym(s):

Ag/AgCl paste, C2130809D5, conductive ink

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice

About This Item

Linear Formula:
Ag/AgCl
NACRES:
NA.23
UNSPSC Code:
12141740
Pricing and availability is not currently available.
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


description

Coverage: 200 cm2 per g (using a 156 mesh polyester screen), Electrodes, Sheet resistivity:<100 miliohms per square (20 micron thick printed on alumina substrate)

form

paste

viscosity

2.0-5.5 Pa.s (Haake RS1 C20/2° TiL at 230 sec-1 at 25°C)

General description

This product has a ratio of silver to silver chloride of 60/40.

Application

  • Highly sensitive determination of heavy metals in water prior to and after remediation using Citrofortunella Microcarpa: This study utilizes Silver-silver chloride (Ag/AgCl) Paste (60:40) in screen printing electrodes for environmental monitoring applications (Palisoc et al., 2021).
  • Screen-printed graphite electrodes as low-cost devices for oxygen gas detection in room-temperature ionic liquids: This research incorporates a silver/silver chloride reference electrode by screen-printing Ag/AgCl paste (60:40) onto a flexible film, exploring its effectiveness in gas sensing technologies (Lee et al., 2017).
  • Simple Portable Voltammetric Sensor Using Anodized Screen-Printed Graphene Electrode for the Quantitative Analysis of p-Hydroxybenzoic Acid in Cosmetics: In this study, silver/silver chloride paste (Ag/AgCl: 60/40) was used to enhance the functionality of screen-printed electrodes for cosmetic analysis (Charoenkitamorn et al., 2022).
  • Dipstick Sensor Based on Molecularly Imprinted Polymer-Coated Screen-Printed Electrodes for Single-Shot Detection of Glucose in Urine Samples: This research features the use of silver/silver chloride (60:40) reference electrode, screen-printed onto plastic for biomedical applications (Caldara et al., 2023).
  • Simultaneous determination of ascorbic acid, dopamine, and uric acid using graphene quantum dots/ionic liquid modified screen-printed carbon electrode: Utilizes carbon ink and silver/silver chloride (Ag/AgCl) paste 60/40 for developing advanced sensor platforms (Kunpatee et al., 2020).

Features and Benefits

Product Benefits
  • Applications in medical diagnostics, environmental sensors
  • High conductivity
  • Low curing temperature

Preparation Note

PROCESSING

  • Screen Printing Equipment: semi-automatic, manual

  • Ink Screen Life: >3 hours

  • Screen Types: polyester, mesh 156 to 230 tpi

Note: Stainless Steel mesh is not recommended, since a paste component can become corrosive in the presence of moisture.Also, plastic palette knives should be used instead of metal knives.

  • Typical Drying Conditions: Dry at 60°C for 30minutes or 80°C for 10minutes in a box oven.

  • Clean up solvent: ethoxyl propanol or seriocol

  • Substrate: polyester, PVC, polycarbonate and alumina

Legal Information

Product of Gwent Electronic Materials Ltd (GEM), part of Sun Chemical Corporation

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
901769901879902497
description

-

description

-

description

-

description

-

viscosity

2.0-5.5 Pa.s (Haake RS1 C20/2° TiL at 230 sec-1 at 25°C)

viscosity

0.72-1.78 Pa.s (Haake RS1 C20/2° TiL at 230 sec-1 at 25°C)

viscosity

45-55 Pa.s

viscosity

12.0-16.0 Pa.s (Haake RS1 C20/2° TiL at 230 sec-1 at 25 °C)

description

Coverage: 200 cm2 per g (using a 156 mesh polyester screen), Sheet resistivity:<100 miliohms per square (20 micron thick printed on alumina substrate), Electrodes

description

Flash point: 90°C, Volume resistivity: 925 ohm cm at 60°C
527 ohm cm at 130°C, Solid content: 44-46% (at 130°C), Coverage: 250-270 cm2 per g (using a 230 mesh stainless steel screen), Electrodes

description

Electrodes, Solid content: 82-85% (120 °C), Volume resistivity: <2.5x10-5 Ω.cm (150°C/30 min), Sheet resistivity: <0.010 Ω/sq/mil (150°C/10 min)

description

Coverage: 305 cm2 per g (using a 230 mesh stainless steel screen with 13 micron emulsion), Insulation and Encapsulation, Solvent Resistance: DMAC − Attack, Solvent Resistance: MEK − Full attack, Solvent Resistance: Acetone − Attack, Solvent Resistance: THF − Attack, Solvent Resistance: DMF− Attack

form

paste

form

paste

form

liquid

form

paste


Signal Word

Warning

Flash Point (°F)

192.2 °F

Flash Point (°C)

89 °C

Target Organs

Nervous system

Hazard Classifications

Aquatic Acute 1 - Aquatic Chronic 1 - Met. Corr. 1 - Repr. 2 - STOT RE 2

Storage Class

10 - Combustible liquids



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library




Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. Will product 901773 work for fabricating the Ag/AgCl reference electrode on a 120 nm Au layer, which is electron-beam evaporated on a Si/SiO2 substrate?

    1 answer
    1. 901773 is not a suitable option for making an Ag/AgCl electrode due to the presence of organic surfactants that may not be thoroughly removable base. Ag/AgCl reference electrode or an Ag/AgCl electrode starting with Ag wire is recommended for electron-beam evaporated on a Si/SiO2 substrate.

      Helpful?

Reviews

No rating value

Active Filters