Skip to Content
Merck
  • Supported liquid membrane-protected molecularly imprinted beads for micro-solid phase extraction of sulfonamides in environmental waters.

Supported liquid membrane-protected molecularly imprinted beads for micro-solid phase extraction of sulfonamides in environmental waters.

Journal of chromatography. A (2014-05-02)
M Díaz-Álvarez, F Barahona, E Turiel, A Martín-Esteban
ABSTRACT

In this work, molecularly imprinted polymer (MIP) beads have been prepared and evaluated for the development of a supported liquid membrane-protected micro-solid phase extraction method for the analysis of sulfonamides (SAs) in aqueous samples. The performance of MIP beads was firstly evaluated in cartridges by conventional solid-phase extraction for the simultaneous analysis of SAs. Afterward, beads were packed into a polypropylene hollow fiber protected by an organic solvent immobilized in the pores of the capillary wall. During the process, the analytes were extracted from the aqueous sample to the immobilized organic solvent and then selectively retained by the MIP beads located inside the capillary. The effect of various experimental parameters as sample pH, time and stirring-rate among others, were studied for the establishment of optimum rebinding conditions. Relative recoveries for all sulfonamides tested in river and reservoir water samples by the proposed method using 100mL water sample spiked with 50μg L-1 of each sulfonamide were within 70-120%, with a relative standard deviation (RSD) <10% (n=3). The detection limits (LODs) were within 0.2-3μgL(-1), depending upon the sulfonamide and the type of water used.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Aluminum oxide, nanopowder, <50 nm particle size (TEM)
Sigma-Aldrich
Aluminum oxide, nanoparticles, <50 nm particle size (DLS), 20 wt. % in isopropanol
Sigma-Aldrich
Sulfadiazine, 99.0-101.0%
Sigma-Aldrich
Sulfachloropyridazine
Sigma-Aldrich
Aluminum oxide, nanowires, diam. × L 2-6 nm × 200-400 nm
Supelco
Aluminum oxide, for the determination of hydrocarbons
Supelco
Toluene, analytical standard
Supelco
Sulfachloropyridazine, VETRANAL®, analytical standard
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Methacrylic acid, contains 250 ppm MEHQ as inhibitor, 99%
Sigma-Aldrich
Aluminum oxide, 99.997% trace metals basis
Sigma-Aldrich
Toluene, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Aluminum oxide, nanoparticles, 30-60 nm particle size (TEM), 20 wt. % in H2O
Sigma-Aldrich
Aluminum oxide, single crystal substrate, <0001>
Sigma-Aldrich
Aluminum oxide, nanopowder, 13 nm primary particle size (TEM), 99.8% trace metals basis
Sigma-Aldrich
Acetonitrile, ≥99.9% (GC)
Sigma-Aldrich
Acetonitrile, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Toluene, suitable for HPLC, 99.9%
Supelco
Toluene, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Residual Solvent - Toluene, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Toluene, ACS reagent, ≥99.5%
Sigma-Aldrich
Aluminum oxide, standard grade, Brockmann I, activated, basic
Sigma-Aldrich
Aluminum oxide, activated, Brockmann I, standard grade, neutral
Sigma-Aldrich
Aluminum oxide, Brockmann I, standard grade, activated, acidic
Sigma-Aldrich
Toluene, Laboratory Reagent, ≥99.3%