46401-U
rac-β-Tocopherol solution
50 mg/mL in hexane, certified reference material
About This Item
Productos recomendados
grade
certified reference material
Quality Level
CofA
current certificate can be downloaded
packaging
ampule of 1 mL
concentration
50 mg/mL in hexane
technique(s)
HPLC: suitable
gas chromatography (GC): suitable
application(s)
pharmaceutical (small molecule)
vitamins, nutraceuticals, and natural products
format
single component solution
storage temp.
-10 to -25°C
InChI
1S/C28H48O2/c1-20(2)11-8-12-21(3)13-9-14-22(4)15-10-17-28(7)18-16-25-24(6)26(29)19-23(5)27(25)30-28/h19-22,29H,8-18H2,1-7H3/t21?,22?,28-/m1/s1
InChI key
WGVKWNUPNGFDFJ-CBIUGAAKSA-N
¿Está buscando productos similares? Visita Guía de comparación de productos
General description
Application
- Simultaneous determination of vitamin A and all four tocopherol isomers in human serum samples by ultra-high performance liquid chromatography (UHPLC) combined with fluorescence detection following their liquid-liquid extraction (LLE)
- Multi-residue analysis of vitamin B (B1, B2, B5, and B9), and vitamin E (α-tocopherol, β-tocopherol, α-tocotrienol, and β-tocotrienol) in grass and grain samples of four different wheat varieties by liquid chromatography electrospray ionization/multistage mass spectrometry (LC-ESI-MS/MS)
- Separation and estimation of four tocopherols and four tocotrienols in pecan nut cultivar samples using non-aqueous reversed-phase high-performance liquid chromatography (NARP-HPLC) coupled with atmospheric pressure chemical ionization-tandem mass spectrometric (APCI-MS/MS) detection
- Analysis of different cold pressed oil samples to detect and quantify eight tocol homologs using a chemometrically-assisted optimized high-performance liquid chromatography (HPLC) with fluorescence detection (FLD) based method
- Development and validation of normal-phase high-performance liquid chromatography (NP-HPLC) method, along with fluorescence detection, to simultaneously determine four tocopherols and four lignans in sesame oil samples
Other Notes
signalword
Danger
Hazard Classifications
Aquatic Chronic 2 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 1 Inhalation - STOT SE 3
target_organs
Central nervous system, Nervous system
Storage Class
3 - Flammable liquids
wgk_germany
WGK 3
flash_point_f
-9.4 °F - closed cup
flash_point_c
-23 °C - closed cup
ppe
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Los clientes también vieron
Protocolos
GB method with Ascentis® Express C30 column achieves baseline resolution for Vitamin A and E critical pair.
GB method with Ascentis® Express C30 column achieves baseline resolution for Vitamin A and E critical pair.
GB method with Ascentis® Express C30 column achieves baseline resolution for Vitamin A and E critical pair.
GB method with Ascentis® Express C30 column achieves baseline resolution for Vitamin A and E critical pair.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico