Saltar al contenido
Merck
Todas las fotos(2)

Documentos clave

S2GPU10RE

Millipore

Sistema de filtración al vacío Millipore® Stericup® Quick Release

pore size 0.22 μm, polyethersulfone membrane, funnel capacity 500 mL, pack of 12 ea

Sinónimos:

SCGPU10RE, Sistema de filtración al vacío estéril Stericup Quick Release-GP

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
41104914
eCl@ss:
32031623
NACRES:
NB.24
En este momento no podemos mostrarle ni los precios ni la disponibilidad

Materiales

polyethersulfone membrane
polystyrene bottle
polystyrene funnel(s)
polystyrene housing

Nivel de calidad

esterilidad

sterile; irradiated

Línea del producto

Stericup®

Características

hydrophilic

envase

pack of 12 ea

Parámetros

45 °C max. temp.

descripción

2.4 mL (hold-up volume)

técnicas

sterile filtration: suitable

Altura

299 mm

capacidad

1000 mL

Diámetro

12.5 cm

diám. del filtro

73 mm

filtración área

40 cm2

embudo capacidad

500 mL

Matriz

Express PLUS

tamaño de poro

0.22 μm pore size

Adaptador

inlet funnel
outlet flask (Receiver)

Condiciones de envío

ambient

Descripción general

Este artículo es un sustituto directo de SCGPU02RE
Trabaje con facilidad y filtre con confianza con los sistemas de filtración Stericup® y Steritop®.

Las unidades de filtración estériles Stericup® y Steritop® utilizan membranas de alto rendimiento fiables para una esterilización por filtración óptima de los reactivos, las disoluciones tampón y los medios. Estos dispositivos combinan caudales y rendimiento superiores con una baja adsorción inespecífica y un diseño estable sin puntas.

Esta unidad de filtración Stericup® con membrana de polietersulfona (PES) y tamaño de poro de 0,22 μm combina una tapa de botella de 500 ml con un matraz receptor de 1000 ml y una tapa para procesamiento y almacenamiento.

Aplicación

Los sistemas Stericup® y Steritop® están diseñados para reducir la formación de espuma y la desnaturalización de las proteínas al tiempo que maximizan el flujo y pueden utilizarse para la esterilización mediante filtración al vacío de disoluciones acuosas como medios para cultivo de tejidos y líquidos biológicos.

  • Medios de cultivo de tejidos +/- aditivos
  • Amortiguadores
  • Disoluciones biológicas
Para uso exclusivo en investigación

Características y beneficios

  • El embudo de filtración Quick Release se desconecta de la botella receptora con solo un cuarto de vuelta—reduciendo así la probabilidad de derrame y haciendo que sea más fácil de manipular sobre la mesa de trabajo o bajo la campana.
  • La identificación del producto en negrita en el embudo de filtración Steritop® muestra claramente las características de la membrana, como su composición y el tamaño de los poros, para una selección de productos rápida y apropiada para la aplicación.
  • El tapón de cierre mediante un clic está bridado y modificado para permitir un fuerte agarre en condiciones húmedas o secas— y un tope táctil confirma el cierre seguro. Preocúpese menos de la posibilidad de derramamiento o contaminación de los contenidos esterilizados.
  • Una amplia superficie esmerilada de escritura en la botella receptora y el color más claro del tapón facilitan el etiquetado claro para mejorar la legibilidad y reducir los frotis ilegibles.
  • La tapa descansa sobre el lateral para evitar el riesgo de contaminación.
  • Las botellas receptoras son apilables para ahorrar espacio de almacenamiento.

Información legal

EXPRESS PLUS is a trademark of Merck KGaA, Darmstadt, Germany
Millipore is a registered trademark of Merck KGaA, Darmstadt, Germany
Stericup is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Artículos

Evaluation of sterile filtration devices for protein preservation in sterile filtration of cell culture media.

Evaluation of sterile filtration devices for protein preservation in sterile filtration of cell culture media.

Evaluation of sterile filtration devices for protein preservation in sterile filtration of cell culture media.

Evaluation of sterile filtration devices for protein preservation in sterile filtration of cell culture media.

Contenido relacionado

This article shows that a PES membrane containing Stericup Quick Release filter provides an alternative for the pluripotent expansion of embryonic stem cells.

This article shows that a PES membrane containing Stericup Quick Release filter provides an alternative for the pluripotent expansion of embryonic stem cells.

This article shows that a PES membrane containing Stericup Quick Release filter provides an alternative for the pluripotent expansion of embryonic stem cells.

This article shows that a PES membrane containing Stericup Quick Release filter provides an alternative for the pluripotent expansion of embryonic stem cells.

Questions

1–10 of 15 Questions  
  1. Are Stericup® and Steritop® filters GMP-certified?

    1 answer
    1. No, Stericup® and Steritop® devices are not GMP-approved.

      Helpful?

  2. What is the difference between classic Stericup® filters and Stericup® “Quick Release” filters?

    1 answer
    1. Stericup® Quick Release, or “QR”, filters feature a connection between funnel filter and receiver bottle that requires only a quarter-turn release to facilitate funnel removal. These filters come fully engaged – there is no need to tighten before use. The receiver bottle cap has flanges on the top surface to improve grip, as well as a positive lock stop to ensure a leak-proof seal with the receiver bottle. Other improvements include a large, frosted writing surface on the receiver bottle and a lighter cap color to facilitate labelling, more prominent volume markings on the filtration funnel and receiver bottle, and a product label with a peel-off lot record strip on the bag for easy viewing in storage.

      Helpful?

  3. What is the maximum vacuum pressure for filtration?

    1 answer
    1. 700 mm Hg (27.5” Hg, 0.9 bar) differential vacuum at 25 °C (77 °F)

      Helpful?

  4. Can Stericup® and Steritop® filters be used to prepare solutions that will be administered to patients?

    1 answer
    1. No, all Stericup® and Steritop® devices are Research Use Only.

      Helpful?

  5. What is the chemical compatibility of the various Stericup® and Steritop® filters?

    What is the chemical compatibility of the various Stericup® and Steritop® filters?

    1 answer
    1. Helpful?

  6. What leachables are detected during filtration processes using Stericup® filters?

    1 answer
    1. We have not performed extractables/leachables studies for our Stericup® filters.

      Helpful?

  7. Can we filter oil-type liquids with Stericup® filters?

    Can we filter oil-type liquids with Stericup® filters?

    1 answer
    1. Likely not, due to pore size/possible fouling/chemical compatibility. Refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf

      Helpful?

  8. Which type of pump should be used with Stericup® and Steritop® vacuum filters?

    Which type of pump should be used with Stericup® and Steritop® vacuum filters?

    1 answer
    1. We recommend our Chemical Duty Pump: https://www.sigmaaldrich.com/product/mm/wp6111560

      Helpful?

  9. What tubing can be used with Stericup® and Steritop® vacuum filters?

    What tubing can be used with Stericup® and Steritop® vacuum filters?

    1 answer
    1. Stericup® and Steritop® filters are fitted with a 1/4” tube adapter. We recommend 3/16 in. (4.8 mm) ID silicone tubing to fit this tube adapter: https://www.sigmaaldrich.com/product/mm/xx7100004

      Helpful?

  10. What Bacterial Endotoxins Test is used?

    1 answer
    1. The test method used complies with USP 85 and EP 2.6.14 to ensure the absence of endotoxin in our products.

      Helpful?

1–10 of 15 Questions  

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico