Saltar al contenido
Merck
Todas las fotos(9)

Documentos clave

MFHV00025

Millipore

Milliflip®-HV Non-sterile Vacuum-driven PVDF Filter Unit

Nonsterile, 50 mL process volume, 0.45 µm pore size, PVDF membrane

Sinónimos:

PVDF nonsterile filter unit, tube top vacuum filter

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
41104921
NACRES:
NB.24
En este momento no podemos mostrarle ni los precios ni la disponibilidad

Materiales

PVDF filter membrane
acrylic housing
polypropylene

Nivel de calidad

esterilidad

non-sterile

Características

holdup volume 0.6 mL
hydrophilic

envase

pack of 25 ea

Parámetros

max. temp. at 45 °C

técnicas

vacuum filtration: suitable

Altura

138 mm

capacidad

50 mL

Diámetro

6.4 cm

diám. del filtro

4 cm

filtración área

7 cm2

embudo capacidad

50 mL

Matriz

Durapore®

tamaño de poro

0.45 μm pore size

Adaptador

double lead thread inlet (with vacuum port)
double lead thread inlet for 50 mL centrifuge tube

Condiciones de envío

ambient

Descripción general

The Milliflip® filter unit is a disposable, vacuum-driven nonsterile filtration system used in the pre-filtration and clarification of water, buffers and aqueous solutions. It is designed to work with standard 50 mL centrifuge tubes, which eliminates sample transfer.

Aplicación

Nonsterile vacuum filtration of water, buffers and aqueous solutions

Características y beneficios

Eliminates messy sample transfer via simple vacuum-assisted system; attaches to any standard 50 ml centrifuge tube eliminating unnecessary materials and risk of spilage; ideal for nonsterile filtration of aqueous and organic solutions used in analytical sample preparation; convenient blue stand helps to hold the filter unit during filtration;

Información legal

Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
MilliFlip is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Questions

1–10 of 17 Questions  
  1. Can one remove the filter and/or use with an additional filter?

    1 answer
    1. These devices are intended for single use only, and the membrane cannot be removed or changed.

      Helpful?

  2. Can I use the filter itself for further investigation or is it packed and sealed?

    1 answer
    1. These devices are designed to be single use only, and the membrane is not removable/changeable.

      Helpful?

  3. Does the tube holder come with it?

    1 answer
    1. Yes, this product includes one tube stand per box of 25 devices. Please see the link below to review additional information available in the product datasheet:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/204/618/20767821-ms.pdf

      Helpful?

  4. What is a Milliflip™ filter unit?

    1 answer
    1. The nonsterile vacuum-driven Milliflip™ filter unit is designed to offer a convenient solution to quickly clarify samples, buffers and reagents prior to analysis.The ready-to-assemble, closed system of the Milliflip™ filtration unit offers an ergonomic design, robust filtration of up to 50 ml, maximizes recovery, saves time, and reduces contamination. There is no sample transfer needed as you can simply filter with a flip of your wrist.

      Helpful?

  5. Why is the liquid flowing out the vacuum tubing line?

    1 answer
    1. There are two recommendations:
      1. Confirm orientation: This is likely being used upside-down. See user manual for correct orientation.
      2. Make sure to use a trap with filtered line to prevent liquid from entering pump or vacuum set-up (i.e. Millex® FG 50mm Cat. SLFG05010)

      Helpful?

  6. What is the maximum centrifugal speed of the conical tube?

    1 answer
    1. 5000 x g (Fixed angle 23, 35, 45-degree rotors)

      Helpful?

  7. Does Milliflip™ have other options for membrane material besides 0.45 µm Durapore® polyvinylidene fluoride (PVDF)?

    1 answer
    1. Milliflip™ is currently only offered in 0.45 µm Durapore® polyvinylidene fluoride (PVDF). However, sterile versions of PES, Nylon and PVDF membranes are available in the Steriflip brand.

      Helpful?

  8. What is the minimum volume that can be filtered?

    1 answer
    1. Sample volume should be greater than 1-2 mL. Filter unit hold-up and tubes’ residual hold-up volume can be ~0.5 mL. It is best to have entire filter surface covered in liquid

      Helpful?

  9. Can I sterilize the Milliflip™ Durapore HV filter?

    1 answer
    1. Sterile version of the Durapore-HV filter can be ordered (Steriflip® HV filter Cat. SE1M003M00)

      Helpful?

  10. Do I have to use vacuum pressure to filter my sample?

    1 answer
    1. Yes, this is a vacuum type of device and processing is performed using vacuum pressure. Many types of vacuum sources may be used including pumps and house vacuum

      Helpful?

1–10 of 17 Questions  

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.