HPLC Analysis of Atrazine Herbicides on Ascentis® Express C18

HPLC Analysis of Atrazine Herbicides on Ascentis® Express C18 application for HPLC

材料

分析柱

产品编号
说明
价格

Ascentis® Express C18, 2.7 μm HPLC 色谱柱

2.7 μm particle size, L × I.D. 10 cm × 3 mm

標準

产品编号
说明
价格

阿特拉津

PESTANAL®, analytical standard

异丙隆

PESTANAL®, analytical standard

利谷隆

PESTANAL®, analytical standard

敌草隆

PESTANAL®, analytical standard

吡唑草胺

PESTANAL®, analytical standard

噻唑隆

PESTANAL®, analytical standard

莠谷隆

PESTANAL®, analytical standard

甲氧隆

PESTANAL®, analytical standard

特丁津-2-羟基

PESTANAL®, analytical standard

绿谷隆

PESTANAL®, analytical standard

草净津

PESTANAL®, analytical standard

环嗪酮

PESTANAL®, analytical standard

CONDITIONS

column

Ascentis Express C18, 10 cm x 3.0 mm I.D., 2.7 μm particles (53814-U)

mobile phase

[A] 20 mM ammonium acetate, pH 6.4 unadjusted; [B] acetonitrile

gradient

20 to 28% B in 11 min; 28 to 65% B in 5 min; held at 65% B for 4 min

flow rate

0.6 mL/min

column temp.

46 °C

detector

UV, 240 nm

injection

5 μL

sample

10-25 μg/mL in 10:90, water: acetonitrile

说明

分析報告

This application demonstrates the suitability of Ascentis Express C18 for the efficient separation of 17 triazine pesticides.

法律資訊

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany