跳转至内容
Merck
  • Characterization of Wax Esters by Electrospray Ionization Tandem Mass Spectrometry: Double Bond Effect and Unusual Product Ions.

Characterization of Wax Esters by Electrospray Ionization Tandem Mass Spectrometry: Double Bond Effect and Unusual Product Ions.

Lipids (2015-07-17)
Jianzhong Chen, Kari B Green, Kelly K Nichols
摘要

A series of different types of wax esters (represented by RCOOR') were systematically studied by using electrospray ionization (ESI) collision-induced dissociation tandem mass spectrometry (MS/MS) along with pseudo MS(3) (in-source dissociation combined with MS/MS) on a quadrupole time-of-flight (Q-TOF) mass spectrometer. The tandem mass spectra patterns resulting from dissociation of ammonium/proton adducts of these wax esters were influenced by the wax ester type and the collision energy applied. The product ions [RCOOH2](+), [RCO](+) and [RCO-H2O](+) that have been reported previously were detected; however, different primary product ions were demonstrated for the three wax ester types including: (1) [RCOOH2](+) for saturated wax esters, (2) [RCOOH2](+), [RCO](+) and [RCO-H2O](+) for unsaturated wax esters containing only one double bond in the fatty acid moiety or with one additional double bond in the fatty alcohol moiety, and (3) [RCOOH2](+) and [RCO](+) for unsaturated wax esters containing a double bond in the fatty alcohol moiety alone. Other fragments included [R'](+) and several series of product ions for all types of wax esters. Interestingly, unusual product ions were detected, such as neutral molecule (including water, methanol and ammonia) adducts of [RCOOH2](+) ions for all types of wax esters and [R'-2H](+) ions for unsaturated fatty acyl-containing wax esters. The patterns of tandem mass spectra for different types of wax esters will inform future identification and quantification approaches of wax esters in biological samples as supported by a preliminary study of quantification of isomeric wax esters in human meibomian gland secretions.

材料
货号
品牌
产品描述

Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
乙酸铵, for molecular biology, ≥98%
Sigma-Aldrich
乙酸铵 溶液, for molecular biology, 7.5 M
Sigma-Aldrich
2-甲基-2-丁烯, ≥95.0% (GC)
Sigma-Aldrich
氯仿, anhydrous, ≥99%, contains 0.5-1.0% ethanol as stabilizer
Sigma-Aldrich
乙酸铵, 99.999% trace metals basis
Sigma-Aldrich
碘化钠, 99.999% trace metals basis
Sigma-Aldrich
氯仿, anhydrous, contains amylenes as stabilizer, ≥99%
Sigma-Aldrich
乙酸铵, reagent grade, ≥98%
Sigma-Aldrich
氯仿, ≥99%, PCR Reagent, contains amylenes as stabilizer
Sigma-Aldrich
乙酸铵, BioXtra, ≥98%
Sigma-Aldrich
油酸油基酯, ≥99%
Sigma-Aldrich
碘化钠, ≥99.99% trace metals basis
Sigma-Aldrich
甲醇, NMR reference standard
Sigma-Aldrich
碘化钠, anhydrous, free-flowing, Redi-Dri, ReagentPlus®, ≥99%
Sigma-Aldrich
2-甲基-2-丁烯, ≥99%, purified by redistillation
Supelco
氯仿, suitable for HPLC, ≥99.8%, contains 0.5-1.0% ethanol as stabilizer
Sigma-Aldrich
甲醇-12C, 99.95 atom % 12C
Sigma-Aldrich
碘化钠, AnhydroBeads, −10 mesh, 99.999% trace metals basis
Sigma-Aldrich
2-甲基-2-丁烯, technical grade, 90%
Sigma-Aldrich
甲醇 溶液, (Methanol:Dimethyl sulfoxide 1:1 (v/v))