  • Comparison of liquid chromatography and supercritical fluid chromatography coupled to compact single quadrupole mass spectrometer for targeted in vitro metabolism assay.

Comparison of liquid chromatography and supercritical fluid chromatography coupled to compact single quadrupole mass spectrometer for targeted in vitro metabolism assay.

Journal of chromatography. A (2014-12-03)
Dany Spaggiari, Florence Mehl, Vincent Desfontaine, Alexandre Grand-Guillaume Perrenoud, Szabolcs Fekete, Serge Rudaz, Davy Guillarme
摘要

The goal of this study was to evaluate the combination of powerful chromatographic methods and compact single quadrupole MS device for simple in vitro cytochrome P450 (CYP) inhibition assay, instead of more expensive triple quadrupole MS/MS detectors. For this purpose, two modern chromatographic approaches (ultra-high pressure liquid chromatography (UHPLC) and ultra-high performance supercritical fluid chromatography (UHPSFC)) were tested in combination with simple MS detector. To show the applicability for an in vitro CYP-mediated metabolism assay using the cocktail approach, a method was first developed in UHPLC-MS to separate a mixture of 8 probe substrates and 8 CYP-specific metabolites. A screening procedure was initially applied to determine the best combination of a column, an organic modifier and a mobile-phase pH, followed by fine tuning of the conditions (i.e., gradient profile, temperature and pH) using HPLC modelling software. A similar sequential method development procedure was also evaluated for UHPSFC-MS. For method development, where peak tracking is necessary, the use of single quadrupole MS was found to be extremely valuable for following the investigated analytes. Ultimately, a baseline separation of the 16 compounds was achieved in both UHPLC-MS and UHPSFC-MS with an analysis time of less than 7 min. In a second series of experiments, sensitivity was evaluated, and LOQ values were between 2 and 100 ng/mL in UHPLC-MS, while they ranged from 2 to 200 ng/mL in UHPSFC-MS. Based on the concentrations employed for the current in vitro phase I metabolism assay, these LOQ values were appropriate for this type of application. Finally, the two analytical methods were applied to in vitro CYP-dependent metabolism testing. Two well-known phytochemical inhibitors, yohimbine and resveratrol, were investigated, and reliable conclusions were drawn from these experiments with both UHPLC-MS and UHPSFC-MS. At the end, the proposed strategy of optimized chromatography combined with simple MS device has been shown to potentially compete with the widely used combination of generic chromatography and highly selective MS/MS device for simple in vitro CYP inhibition assays. In addition, our analytical method may be easier to use in a routine environment; the instrument cost is significantly reduced and the two developed methods fit for purpose.

材料
货号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
甲醇, suitable for HPLC, ≥99.9%
Sigma-Aldrich
2-丙醇, suitable for HPLC, 99.9%
Sigma-Aldrich
2-丙醇, ACS reagent, ≥99.5%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
氢氧化铵 溶液, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
乙酸, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
乙腈, HPLC Plus, ≥99.9%
Sigma-Aldrich
乙酸, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
氢氧化钾, ACS reagent, ≥85%, pellets
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
庚烷, suitable for HPLC, ≥99%
Sigma-Aldrich
HEPES, ≥99.5% (titration)
Sigma-Aldrich
甲酸, reagent grade, ≥95%
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%
Sigma-Aldrich
庚烷, ReagentPlus®, 99%
Sigma-Aldrich
甲酸, ACS reagent, ≥96%
Sigma-Aldrich
HEPES, BioPerformance Certified, ≥99.5% (titration), suitable for cell culture
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
氢氧化铵 溶液, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
氢氧化钾, reagent grade, 90%, flakes
Sigma-Aldrich
2-丙醇, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
乙腈, for HPLC, for UV, ≥99.9% (GC)
Sigma-Aldrich
异丙醇, meets USP testing specifications
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙酸, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
氢氧化钾 溶液, 45 wt. % in H2O
Sigma-Aldrich
氢氧化钾, semiconductor grade, pellets, 99.99% trace metals basis (Purity excludes sodium content.)
Sigma-Aldrich
乙酸 溶液, suitable for HPLC
Sigma-Aldrich
甲醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)