推荐产品
等級
analytical standard
技術
HPLC: suitable
gas chromatography (GC): suitable
mp
118-120 °C
形式
neat
SMILES 字串
CN[C@@H](C)[C@@H](O)c1ccccc1
InChI
1S/C10H15NO/c1-8(11-2)10(12)9-6-4-3-5-7-9/h3-8,10-12H,1-2H3/t8-,10+/m0/s1
InChI 密鑰
KWGRBVOPPLSCSI-WCBMZHEXSA-N
正在寻找类似产品? 访问 产品对比指南
應用
(+)-Pseudoephedrine may be used as a reference standard in the determination of pseudoephedrine in pharmaceutical formulations using high performance thin layer chromatography (HPTLC).
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
生化/生理作用
非选择性肾上腺素激动剂;减充血剂
訊號詞
Warning
危險分類
Acute Tox. 4 Oral - Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
標靶器官
Respiratory system
儲存類別代碼
11 - Combustible Solids
水污染物質分類(WGK)
WGK 3
閃點(°F)
Not applicable
閃點(°C)
Not applicable
個人防護裝備
dust mask type N95 (US), Eyeshields, Gloves
其他客户在看
Stability indicating HPTLC method for the simultaneous determination of pseudoephedrine and cetirizine in pharmaceutical formulations.
Makhija N S and Vavia R P.
Journal of Pharmaceutical and Biomedical Analysis, 25(3-4), 663-667 (2001)
Pablo Vazquez-Roig et al.
The Science of the total environment, 494-495, 49-57 (2014-07-17)
The enantiomeric and diastereomeric profiling of chiral pharmaceuticals (ephedrine, norephedrine, atenolol and venlafaxine) and illicit drugs (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxy-N-methylamphetamine (MDMA) and 3,4-methylenedioxy-N-ethylamphetamine (MDEA)) was undertaken over a period of fourteen consecutive days in three wastewater treatment plants (WWTPs)
Sian E Evans et al.
Analytica chimica acta, 882, 112-126 (2015-06-05)
This is the first study presenting a multi-residue method allowing for comprehensive analysis of several chiral pharmacologically active compounds (cPACs) including beta-blockers, antidepressants and amphetamines in wastewater and digested sludge at the enantiomeric level. Analysis of both the liquid and
Aurélie Periat et al.
Journal of chromatography. A, 1356, 211-220 (2014-07-16)
In this study, the influence of electrospray ionization (ESI) source design on the overall sensitivity achieved in hydrophilic interaction chromatography (HILIC) and reversed phase liquid chromatography (RPLC), was investigated. State-of-the-art triple quadrupole mass analyzers from AB Sciex, Agilent Technologies and
Kristiane de Cássia Mariotti et al.
Journal of analytical toxicology, 38(7), 432-437 (2014-07-21)
Brazil is considered one of the countries with the highest number of amphetamine-type stimulant (ATS) users worldwide, mainly diethylpropion (DIE) and fenproporex (FEN). The use of ATS is mostly linked to diverted prescription stimulants and this misuse is widely associated
Chromatograms
application for HPLC我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门