跳转至内容
Merck

B5763

Sigma-Aldrich

N --丁基二甲基硅基- N -甲基三氟乙酰胺

别名:

MTBSTFA

登录查看公司和协议定价


About This Item

线性分子式:
CF3CON(CH3)Si(CH3)2C(CH3)3
CAS号:
分子量:
241.33
Beilstein:
3606546
MDL號碼:
分類程式碼代碼:
12352000

折射率

n20/D 1.402 (lit.)

bp

172-175 °C (lit.)

密度

1.036 g/mL at 25 °C (lit.)

儲存溫度

−20°C

SMILES 字串

CN(C(=O)C(F)(F)F)[Si](C)(C)C(C)(C)C

InChI

1S/C9H18F3NOSi/c1-8(2,3)15(5,6)13(4)7(14)9(10,11)12/h1-6H3

InChI 密鑰

QRKUHYFDBWGLHJ-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

應用

有效的硅烷化试剂,对湿度的敏感性比其他试剂低。

取代透過

象形圖

Flame

訊號詞

Warning

危險聲明

危險分類

Flam. Liq. 3

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 3

閃點(°F)

113.0 °F - closed cup

閃點(°C)

45 °C - closed cup

個人防護裝備

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Xiaowei Wang et al.
Journal of chromatography. A, 1216(35), 6267-6273 (2009-07-31)
A sample pretreatment method for the determination of 18 chlorophenols (CPs) in aqueous samples by derivatization liquid-phase microextraction (LPME) was investigated using gas chromatography-mass spectrometry. Derivatization reagent was spiked into the extraction solvent to combine derivatization and extraction into one
Stephane Morville et al.
Journal of environmental monitoring : JEM, 6(12), 963-966 (2004-11-30)
A method using GC-MS and derivatization with N-(t-butyldimethylsilyl)-N-methyltrifluoroacetamide (MTBSTFA) was developed for the analysis of 20 phenolic compounds in atmospheric samples (gas and particles). Air sampling was carried out using a Hi-Vol sampler with glass fibre filter and XAD-2 resin
R Montes et al.
Journal of chromatography. A, 1216(2), 205-210 (2008-12-17)
A fast and novel sample preparation procedure for the determination of triclosan (TCS) and methyltriclosan (MTCS) in water samples is presented. Dispersive liquid-liquid microextraction, using a ternary mixture consisting of a disperser, an extractant and N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA) as derivatization reagent
Martin Adiels et al.
Rapid communications in mass spectrometry : RCM, 24(5), 586-592 (2010-02-09)
Stable isotope kinetic studies play an important role in the study of very-low density lipoprotein (VLDL) metabolism, including basic and clinical research. Today, [1,1,2,3,3-(2)H(5)]glycerol is the most cost-effective alternative to measure glycerol and triglyceride kinetics. Recycling of glycerol from glycolysis
Xiaowei Wang et al.
Analytica chimica acta, 753, 57-63 (2012-10-31)
A sample preparation method for the determination of hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) in sediment samples was developed using gas chromatography-mass spectrometry (GC-MS). Dispersive liquid-liquid microextraction (DLLME) with derivatization was performed following the subcritical water extraction (SWE) that provided which

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门