推荐产品
等級
certified reference material
pharmaceutical secondary standard
品質等級
agency
traceable to NIST 3005
traceable to USP 1601849
蒸汽密度
3.7 (vs air)
蒸汽壓力
9 mmHg ( 20 °C)
CofA
current certificate can be downloaded
自燃溫度
984 °F
expl. lim.
7 %
技術
HPLC: suitable
gas chromatography (GC): suitable
折射率
n20/D 1.495 (lit.)
bp
138 °C (lit.)
mp
12-13 °C (lit.)
密度
0.861 g/mL at 20 °C (lit.)
應用
pharmaceutical (small molecule)
格式
neat
儲存溫度
2-30°C
SMILES 字串
Cc1ccc(C)cc1
InChI
1S/C8H10/c1-7-3-5-8(2)6-4-7/h3-6H,1-2H3
InChI 密鑰
URLKBWYHVLBVBO-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
相关类别
一般說明
Pharmaceutical secondary standards for application in quality control, provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to the preparation of in-house working standards.
應用
p-Xylene may be used as a pharmaceutical reference standard for the determination of the analyte in pharmaceutical formulations by chromatography techniques.
These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.
分析報告
These secondary standards offer multi-traceability to the USP, EP (PhEur) and BP primary standards, where they are available.
其他說明
This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.
腳註
To see an example of a Certificate of Analysis for this material enter LRAB8973 in the slot below. This is an example certificate only and may not be the lot that you receive.
推薦產品
Find a digital Reference Material for this product available on our online platform ChemisTwin® for NMR. You can use this digital equivalent on ChemisTwin® for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here and start your free trial.
訊號詞
Danger
危險分類
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Aquatic Chronic 3 - Asp. Tox. 1 - Eye Irrit. 2 - Flam. Liq. 3 - Skin Irrit. 2 - STOT SE 3
標靶器官
Respiratory system
儲存類別代碼
3 - Flammable liquids
水污染物質分類(WGK)
WGK 2
閃點(°F)
80.6 °F - closed cup
閃點(°C)
27 °C - closed cup
其他客户在看
Semi-automated peak trapping recycle chromatography instrument for peak purity investigations
Journal of Chromatography A, 1133(1-2), 104-111 (2006)
High-speed analysis of residual solvents by flow-modulation gas chromatography
Journal of Chromatography A, 1027(1-2), 75-82 (2004)
FEMS microbiology ecology, 80(3), 722-734 (2012-03-03)
The treatment of air contaminated with toluene, ethylbenzene, and p-xylene was assayed in three laboratory-scale biofilters, each consisting of two modules connected in series, packed with a pelletized organic fertilizer and inoculated with a toluene-degrading liquid enrichment culture. Biofilters were
Toxicology and industrial health, 28(9), 796-819 (2011-11-09)
There is accumulating epidemiological evidence that exposure to some solvents, metals, asphyxiants and other substances in humans is associated with an increased risk of acquiring hearing loss. Furthermore, simultaneous and successive exposure to certain chemicals along with noise can increase
Journal of hazardous materials, 185(2-3), 1019-1026 (2010-10-30)
The influence of water irrigation on both the long-term and short-term performance of p-xylene biodegradation under several organic loading scenarios was investigated using an organic packing material composed of pelletised sawdust and pig manure. Process operation in a modular biofilter
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门