材料
polyester support
polyethersulfone membrane (Hydrophilic (PES))
polypropylene housing (Gamma Stable)
silicone O-ring
品質等級
滅菌相容性
autoclavable compatible
gamma compatible
產品線
Opticap®
特點
hydrophilic
技術
prefiltration: suitable
長度 × 寬度
83.9 cm (32.6 in.) × 8.9 cm (3.5 in.)
過濾面積
1.73 m2 (18.6 ft2)
基質
Milligard® PES
pore size
1.2/0.8 μm pore size
接頭
hose barb (6/8 in. outlet)
inlet and outlet for 1.5 in. (Sanitary Flange )
一般說明
Milligard® PES 1.2/0.8 μm filters are designed for reliable particulate removal from a broad range of fluid streams. When used upstream of sterilizing-grade filters or other unit operations, they improve processing efficiency.
Milligard® PES filters are supported by the TM="Emprove"] Program which consolidates product specific testing, quality and regulatory information to simplify compliance needs.
Milligard® PES filters are supported by the TM="Emprove"] Program which consolidates product specific testing, quality and regulatory information to simplify compliance needs.
應用
Prefiltration
特點和優勢
Fast flow and high throughput
Predictable scalability from small-scale to production-size devices
High thermal stability: compatible with steam-in-place and autoclave sterilization methods
Single-use, gamma-ready formats
Caustic stable
Predictable scalability from small-scale to production-size devices
High thermal stability: compatible with steam-in-place and autoclave sterilization methods
Single-use, gamma-ready formats
Caustic stable
包裝
PE Bag
其他說明
Directions for Use
Organism Retention: Microorganism
Mode of Action: Filtration (size exclusion)
Application: BioProcessing
Intended Use: Reduction or removal of microorganism/bioburden
Instructions for Use: Please refer to Opticap® Small Scale 300 Capsule, XL, XLT and T-line Capsules User Guide
Storage Statement: Store in dry location
Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Organism Retention: Microorganism
Mode of Action: Filtration (size exclusion)
Application: BioProcessing
Intended Use: Reduction or removal of microorganism/bioburden
Instructions for Use: Please refer to Opticap® Small Scale 300 Capsule, XL, XLT and T-line Capsules User Guide
Storage Statement: Store in dry location
Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
法律資訊
MILLIGARD is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany
免責聲明
Filters are designed, developed and manufactured in accordance with a Quality Management System approved by an accredited registering body to the ISO 9001 Quality Systems Standard. Certificate of Quality is available online for all filters.