材料
polyester support
polypropylene housing
silicone seal
vent cap (gamma stable polypropylene)
品質等級
法律遵循
meets FDA 21 CFR 177-182 (all component materials)
無菌
non-sterile
滅菌相容性
gamma compatible
產品線
Opticap® XLT 10
特點
hydrophilic
製造商/商標名
Millipore Express®
參數
≤54.2 mL/min air diffusion at 3.45 bar (50 psig) (in water)
0.07 bar max. differential pressure (1 psi) at 135 °C (Reverse)
1 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.07 bar max. differential pressure (30 psi) at 25 °C (Reverse)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet pressure
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
80 psig max. inlet pressure
技術
sterile filtration: suitable
長度
14.8 in.
寬度
4.2 in.
柱標稱長度
10 in. (25 cm)
過濾器直徑
4.2 in. (10.7 cm)
過濾器尺寸
10 in.
過濾面積
1.0 m2
雜質
≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
基質
Millipore Express® SHR ((w/Prefilter High Area))
pore size
0.5/0.1 μm pore size
起泡點
≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water
接頭
1/4 in. drain/vent connection ( hose barb with double o-ring seal)
(38 mm (1 1/2 in.) Sanitary Flange Inlet and 25 mm (1 in.) Hose Barb Outlet)
應用
filtration
正在寻找类似产品? 访问 产品对比指南
相关类别
一般說明
特點和優勢
包裝
準備報告
This product was manufactured with a MILLIPORE EXPRESS® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
分析報告
TOC/Conductivity: After sterilization and a controlled water flush of 20 L, samples exhibited <500 ppb TOC per USP 643 and <1.3 μS/cm per USP 645 at 25 °C.
Bacterial Retention: Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 107 CFU/cm2 using ASTM® F838 methodology.
其他說明
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS® Membrane user guide
- Storage Statement: Please refer Filters with MILLIPORE EXPRESS® Membrane user guide
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
法律資訊