材料
borosilicate glass fiber (BGF) membrane
mixed cellulose esters (MCE) membrane
polypropylene device
polypropylene support (spun bonded)
silicone seal
品質等級
法律遵循
meets FDA 21 CFR 177–182 (all component materials)
無菌
non-sterile
滅菌相容性
autoclavable compatible
steam-in-place compatible
產品線
Polysep™
特點
hydrophilic
製造商/商標名
Polysep™ II
參數
3.5 bar max. differential pressure (50 psid) at 25 °C
技術
prefiltration: suitable
長度
40 in.
寬度
2.7 in.
柱標稱長度
40 in. (100 cm)
設備尺寸
40 in.
過濾器直徑
2.8 in.
過濾器過濾面積
1.84 m2
雜質
≤0.5 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
基質
Polysep™ II
pore size
2.0/1.2 μm nominal pore size
2.0/1.2 μm pore size
柱代碼
Code 0
正在寻找类似产品? 访问 产品对比指南
一般說明
Device Configuration: Cartridge
Cartridge Type: Liquid
Filter Grade: Prefilter
Cartridge Type: Liquid
Filter Grade: Prefilter
應用
mAb & r-protein intermediates; Plasma; Vaccines & viral vectors; SVPs LVPs; Cell Culture; Media Filtration; Colloid Removal; Lipid Removal
特點和優勢
Format: Double Layer
包裝
Double Easy-Open bag
準備報告
Sanitization: 30 min with hot water at 80 °C
Sterilization Method: 10 autoclave cycles or SIP at 121 °C for 30 min
This product was manufactured with a Millipore® media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
分析報告
After autoclaving and a 24 hour soak in ASTM® Type 1 reagent grade water at controlled room temperature, extractables level was ≤140 mg per 10-inch element after a 5000 mL flush.
Cartridges meet the requirements of the USP Oxidizable Substances Test after a water flush of 5000 mL per 10 inch Element
其他說明
Directions for Use:
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer first page of Visual Inspection Guide and introduction section of Mixed cellulose esters Tech Brief
- Storage Statement: Please refer Mixed cellulose esters Tech Brief
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
The product is manufuactured in a facility with a Quality Management System approved by an accredited registering body to an ISO 9001 Quality Systems Standard.
法律資訊
ASTM is a registered trademark of American Society for Testing and Materials
Millipore is a registered trademark of Merck KGaA, Darmstadt, Germany
Polysep is a trademark of Sigma-Aldrich Co. LLC
未找到合适的产品?
试试我们的产品选型工具.
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门