推荐产品
品質等級
化驗
≥95% (HPLC)
形狀
solid
製造商/商標名
Calbiochem®
儲存條件
OK to freeze
protect from light
顏色
pale green
溶解度
DMSO: 0.5 mg/mL
ethanol: 3 mg/mL
運輸包裝
ambient
儲存溫度
2-8°C
InChI
1S/C15H14N2S/c1-17(2)12-9-7-11(8-10-12)15-16-13-5-3-4-6-14(13)18-15/h3-10H,1-2H3
InChI 密鑰
HYKGLCSXVAAXNC-UHFFFAOYSA-N
一般說明
A 2-arylbenzothiazole compound that acts as an inhibitor against the ATP-dependent Photinus pyralis (lucPpy) and Photuris pennsylvanica (lucPpe) luciferase activity (IC50 = 0.2 and 0.32 µM, respectively, with 10 µM ATP, 10 µM luciferin, and 10 nM respective enzyme). Unlike Luciferase Inhibitor I (Cat. No. 119113), Luciferase Inhibitor II is competitive with respect to luciferin and exhibits reduced potency against lucPpe-based commercial luciferase-luciferin formulations with high luciferin concentration (IC50 = 10 µM against Promega′s Kinase-Glo; ineffective against Kinase-Glo Plus and Kinase-Glo Max; at a 3-fold formulation dilution and 6.77 µM ATP).
A 2-arylbenzothiazole compound that acts as an inhibitor against the ATP-dependent Photinus pyralis (lucPpy) and Photuris pennsylvanica (lucPpe) luciferase activity (IC50 = 0.2 and 0.32 µM, respectively, with 10 µM ATP, 10 µM luciferin, and 10 nM respective enzyme). Unlike Luciferase Inhibitor I (Cat. No. 119113), Luciferase Inhibitor II is competitive with respect to luciferin and exhibits reduced potency against lucPpe-based commercial luciferase-luciferin formulations with high luciferin concentration (IC50 = 10 µM against Promega′s Kinase-Glo; ineffective against Kinase-Glo Plus and Kinase-Glo Max; at a 3-fold formulation dilution and 6.77 µM ATP).
包裝
Packaged under inert gas
警告
Toxicity: Harmful (C)
重構
Following reconstitution, aliquot and freeze (-20°C). Stock solutions are stable for up to 3 months at -20°C.
其他說明
Auld, D.S., et al. 2009. J. Med. Chem.52, 1450.
Auld, D.S., et al. 2008. J. Med. Chem.51, 2372.
Auld, D.S., et al. 2008. J. Med. Chem.51, 2372.
法律資訊
Marketed by Promega Corp. under the registered trademarks.
CALBIOCHEM is a registered trademark of Merck KGaA, Darmstadt, Germany
儲存類別代碼
11 - Combustible Solids
水污染物質分類(WGK)
WGK 3
閃點(°F)
Not applicable
閃點(°C)
Not applicable
STAR protocols, 2(3), 100658-100658 (2021-07-22)
Here, we describe an optimized protocol to identify specific nuclear receptor ligands. First, to rule out any compound interference with luciferase activity per se, we describe an in vitro assay assessing potential inhibition or activation of luciferase enzymatic activity. Second
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门