1.11764
HPTLC plates, Silica gel 60 F₂₅₄ AMD,extra thin
pkg of 25 plates, plate L × W 20 mm × 10 cm, according to DIN 38407-F11, glass support
Sign Into View Organizational & Contract Pricing
All Photos(1)
About This Item
Recommended Products
material
glass support
silica gel 60 matrix
Quality Level
Agency
according to DIN 38407-F11
feature
binder Organic Polymer
fluorescent indicator
packaging
pkg of 25 plates
technique(s)
thin layer chromatography (TLC): suitable
layer thickness
100 μm
plate L × W
20 mm × 10 cm
particle size
5-6 μm
pore size
60 Å medium pore diameter
storage temp.
15-25°C
Related Categories
General description
25 Glass plates 20 x 10 cm for AMD acc. to DIN 38407-F11
HPTLC Plates AMD with extra thin layer of only 100 µm have been specially developed for even more demanding application such as automated multiple development (AMD). It combines the repeatedly development of the plate in the same direction and reproducible gradient elution. AMD development provides extremely narrow bands, allowing the complete resolution of to 40 components on 60 mm distance.
Linkage
Replaces: 11764-6; 11764
Analysis Note
Specific surface area (according to BET; 5-Pt. measurement): 480 - 540 m²/g
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 80 - 120 µm
Deviation of layer thickness per plate: ≤ 30 µm
Chromatographic testing:
colour test
hRf-values
- bleu vif organol, colour test, lipophile:
14 - 20
- Ceres Black G, colour test, lipophile: 35 - 43
- ceres Violet brn, colour test, lipophile: 52 - 60
separation number (colourtest, lipophile): ≥ 10.0
Typical value determined on a conditioned plate
Eluent: toluene (45% rel. humidity)
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 80 - 120 µm
Deviation of layer thickness per plate: ≤ 30 µm
Chromatographic testing:
colour test
hRf-values
- bleu vif organol, colour test, lipophile:
14 - 20
- Ceres Black G, colour test, lipophile: 35 - 43
- ceres Violet brn, colour test, lipophile: 52 - 60
separation number (colourtest, lipophile): ≥ 10.0
Typical value determined on a conditioned plate
Eluent: toluene (45% rel. humidity)
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service