90220-001
RNAstable®
96-well plate, for room temp preservation of RNA
Sign Into View Organizational & Contract Pricing
All Photos(3)
About This Item
Recommended Products
grade
for molecular biology
form
dry
usage
96 reactions
greener alternative product characteristics
Design for Energy Efficiency
Learn more about the Principles of Green Chemistry.
greener alternative category
storage temp.
room temp
General description
SampleMatrix® by Biomatrica® is a proprietary core technology to stabilize and protect biological materials at room temperature without degradation. The SampleMatrix technology was designed by combining extremophile biology that enables long-term survival of organisms in extremely dry environments, with synthetic chemistry.
RNAstable® preserves RNA samples at room temperature. Each tube or plate contains RNAstable® as a coating at the bottom of the tube or well, which protects picogram to microgram amounts of RNA. This medium is completely dissolvable and ensures total and quantitative sample recovery.
We are committed to bringing you Greener Alternative Products, which adhere to one or more of The 12 Principles of Greener Chemistry. This product was Designed for Energy Efficiency. To see how Stanford incorporated Biomatrica Technology and saved substantial amounts of energy, see their published study:
Biomatrica technology enables safe storage of biological material at room temperature.
RNAstable® preserves RNA samples at room temperature. Each tube or plate contains RNAstable® as a coating at the bottom of the tube or well, which protects picogram to microgram amounts of RNA. This medium is completely dissolvable and ensures total and quantitative sample recovery.
We are committed to bringing you Greener Alternative Products, which adhere to one or more of The 12 Principles of Greener Chemistry. This product was Designed for Energy Efficiency. To see how Stanford incorporated Biomatrica Technology and saved substantial amounts of energy, see their published study:
Biomatrica technology enables safe storage of biological material at room temperature.
Features and Benefits
- Preserves RNA at ambient temperatures without degradation
- Eliminates the need to store RNA in freezers or to ship on dry ice
- Concentrates RNA more effectively than other methods
- Compatible with most downstream applications
Packaging
- (1) RNAstable® 96-Well Plate
- Hinged lid provides additional sample protection
- (1) tube of sterile water
- Quick Reference Protocol
- Barcode-labeled for sample tracking
- Enclosed in re-sealable moisture-barrier foil pouch
Legal Information
Biomatrica is a registered trademark of Biomatrica
RNAstable is a registered trademark of Biomatrica
SampleMatrix is a registered trademark of Biomatrica
related product
Product No.
Description
Pricing
Storage Class Code
12 - Non Combustible Liquids
WGK
WGK 3
Flash Point(F)
Not applicable
Flash Point(C)
Not applicable
Choose from one of the most recent versions:
Certificates of Analysis (COA)
Don't see the Right Version?
If you require a particular version, you can look up a specific certificate by the Lot or Batch number.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
BioTechniques, 47(2), 667-668 (2009-09-10)
RNA integrity is a critical factor in obtaining meaningful gene expression data. Current methodologies rely on maintaining samples in cold environments during collection, transport, processing, and storage procedures, which are also extremely time-sensitive. Several RNA storage products are commercially available
PloS one, 7(1), e30244-e30244 (2012-02-01)
In this study, mRNA-Seq was used to characterize and compare the leukocyte transcriptomes from two taurine breeds (Holstein and Jersey), and one indicine breed (Cholistani). At the genomic level, we identified breed-specific base changes in protein coding regions. Among 7,793,425
The Journal of infectious diseases, 201 Suppl 1, S27-S36 (2010-03-17)
RNA remains the most informative and accurate biomarker for human immunodeficiency virus type 1 load diagnostics and for surveillance of drug resistance markers. Viral load testing by nucleic acid amplification currently is a complex and expensive test that is restricted
Science (New York, N.Y.), 345(6202), 1369-1372 (2014-09-13)
In its largest outbreak, Ebola virus disease is spreading through Guinea, Liberia, Sierra Leone, and Nigeria. We sequenced 99 Ebola virus genomes from 78 patients in Sierra Leone to ~2000× coverage. We observed a rapid accumulation of interhost and intrahost
Journal of virological methods, 182(1-2), 104-110 (2012-03-22)
Two approaches to stabilize viral nucleic acid in processed clinical specimens were evaluated. HIV-1 RNA extracted from clinical specimens was stabilized in a dry matrix in a commercial product (RNAstable, Biomatrica, San Diego, CA, USA) and in a reverse-transcription reaction
Articles
RNAstable® preserves RNA via anhydrobiosis principles, enabling ambient temp storage and shipping.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service