Recommended Products
vapor density
2.7 (vs air)
vapor pressure
11.69 psi ( 20 °C)
32.33 psi ( 55 °C)
product line
ReagentPlus®
Assay
≥99%
autoignition temp.
1353 °F
expl. lim.
19 %
refractive index
n20/D 1.389 (lit.)
bp
52 °C (lit.)
mp
−112 °C (lit.)
density
1.104 g/mL at 25 °C (lit.)
SMILES string
CC(Cl)=O
InChI
1S/C2H3ClO/c1-2(3)4/h1H3
InChI key
WETWJCDKMRHUPV-UHFFFAOYSA-N
Looking for similar products? Visit Product Comparison Guide
Legal Information
ReagentPlus is a registered trademark of Merck KGaA, Darmstadt, Germany
replaced by
Product No.
Description
Pricing
Signal Word
Danger
Hazard Statements
Precautionary Statements
Hazard Classifications
Eye Dam. 1 - Flam. Liq. 2 - Skin Corr. 1B
Supplementary Hazards
Storage Class Code
3 - Flammable liquids
WGK
WGK 1
Flash Point(F)
41.0 °F - closed cup
Flash Point(C)
5 °C - closed cup
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Journal of the American Chemical Society, 131(14), 5014-5015 (2009-03-27)
A microfluidic high-resolution NMR flow probe based on a novel stripline detector chip is demonstrated. This tool is invaluable for the in situ monitoring of reactions performed in microreactors. As an example, the acetylation of benzyl alcohol with acetyl chloride
The Journal of organic chemistry, 76(14), 5832-5837 (2011-05-27)
A new reagent system comprising acetyl chloride, silver nitrate, and acetonitrile has been developed for the synthesis of 2-nitroglycals from the corresponding glycals. Under certain conditions, the formation of 2-nitro-1-acetamido sugars has also been observed. In addition, a few other
The journal of physical chemistry. A, 114(27), 7275-7283 (2010-06-24)
In one-photon dissociation of gaseous acetyl chloride at 248 nm, time-resolved Fourier-transform infrared emission spectroscopy is used to detect the fragments of HCl, CO, and CH(2) in the presence of Ar or O(2). The high-resolution spectra of HCl and CO
Analytical chemistry, 79(11), 3989-3995 (2007-05-05)
The wide range of protein concentrations found in biological matrixes presents a formidable analytical challenge in proteomics experiments. It is predicted that low-abundance proteins are the likely clinically relevant targets in disease-based proteomics analyses. To effectively analyze low-abundance proteins by
Thrombosis and haemostasis, 113(6), 1278-1288 (2015-03-20)
Zinc circulates free in plasma at a concentration of 0.1-2 µM, but its levels increase locally when it is released from activated platelets. Although zinc influences many processes in haemostasis, its effect on fibrinolysis has not been thoroughly investigated. Using
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service