452130
Poly(methyl methacrylate), isotactic
>80% isotactic
Synonym(s):
Isotactic PMMA, Isotactic methyl methacrylate polymer, Isotactic poly(methyl methacrylate)
Sign Into View Organizational & Contract Pricing
All Photos(1)
About This Item
Recommended Products
Quality Level
form
solid
density
1.2 g/mL at 25 °C (lit.)
InChI
1S/C12H18N3O8PS/c1-4-21-24(18,22-5-2)23-11(17)10(8-7-25-12(13)14-8)15-20-6-9(16)19-3/h7H,4-6H2,1-3H3,(H2,13,14)/b15-10-
InChI key
DOXUHDDTLHKPOE-GDNBJRDFSA-N
General description
i-PMMA can be prepared from t-C4H9MgBr. Structure of crystalline isotactic poly(methyl methacrylate) (i-PMMA) was investigated by X-ray diffraction and infra red spectroscopic techniques.
Application
The polymeric blend of isotatic (i-) poly-(methyl methacrylate) & 6,13-bis(triisopropylsilylethynyl) pentacene can be used to prepare thin films transistors (TFTs).
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point(F)
Not applicable
Flash Point(C)
Not applicable
Personal Protective Equipment
dust mask type N95 (US), Eyeshields, Gloves
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
Self?assembled organic channel/polymer dielectric layer for organic thin?film transistor applications.
AIP Conference Proceedings, 847, 1399-1399 (2011)
Structure of isotactic poly (methyl methacrylate).
Macromolecules, 3(4), 441-447 (1970)
Journal of hazardous materials, 248-249, 401-406 (2013-02-19)
It was demonstrated that a thin film of chemically exfoliated graphene flakes, blended with poly(methyl methacrylate), could be used as a chemiresistor sensor for the sensitive and selective determination of formaldehyde vapor. Formaldehyde adsorption on the sensing film led to
Molecules (Basel, Switzerland), 18(3), 3152-3167 (2013-03-13)
Polymethylmethacrylate-graphene (PMMA/RGO) nanocomposites were prepared via in situ bulk polymerization using two different preparation techniques. In the first approach, a mixture of graphite oxide (GO) and methylmethacrylate monomers (MMA) were polymerized using a bulk polymerization method with a free radical
Simcoe cannula as an anterior chamber maintainer for intraocular lens implantation.
Journal of cataract and refractive surgery, 39(4), 650-651 (2013-03-26)
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service