P8791

Sigma-Aldrich

Polyglycine

mol wt 500-5,000

Sinónimos:

Glycine homopolymer

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Número de CAS:
MDL number:
UNSPSC Code:
12352202
eCl@ss:
32160406
PubChem Substance ID:
NACRES:
NA.26

form

lyophilized powder

Quality Level

mol wt

500-5,000

color

white to light yellow

mp

300 °C

storage temp.

−20°C

SMILES string

NCC(O)=O

InChI

1S/C2H5NO2/c3-1-2(4)5/h1,3H2,(H,4,5)

InChI key

DHMQDGOQFOQNFH-UHFFFAOYSA-N

Gene Information

¿Está buscando productos similares? Visita Guía de comparación de productos

Application

Polyglycine has been used as an external intensity standard for measuring cross polarization (CP) nuclear magnetic resonance (NMR) spectrum measurements and ion mobility mass spectrometry. It is suitable for use as a model for UV resonance Raman spectroscopy studies.

Biochem/physiol Actions

Polyglycine exists in two forms, namely the polyglycine I (PGI) with anti-parallel β-sheet structure and polyglycine II (PGII) with extended 31-helix. It is a most flexible polypeptide with minimal steric hindrance and its solubility increases in the presence of lithium ions. It is present in mammals and plants. Polyglycine stretch associated with the chloroplast membrane protein, Toc5 is essential for envelop sorting.

Preparation Note

Prepared by phosphorylation.

Other Notes

For additional technical information on polyamino acids please visit the Polyamino acid FAQ resource.

Storage Class

11 - Combustible Solids

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Ion mobility mass spectrometry of peptide ions: effects of drift gas and calibration strategies
Bush MF, et al.
Analytical Chemistry, 84(16) (2012)
Ohki Kambara et al.
Biopolymers, 93(8), 735-739 (2010-06-03)
Poly-L-lysine is known to have three different secondary structures depending on solvent conditions because of its flexible nature. In previous work (Kambara et al., Phys Chem Chem Phys 2008, 10, 5042-5044), we observed two different types of structural changes in
Aykut Erbaş et al.
Biophysical journal, 104(6), 1285-1295 (2013-03-27)
Friction within globular proteins or between adhering macromolecules crucially determines the kinetics of protein folding, the formation, and the relaxation of self-assembled molecular systems. One fundamental question is how these friction effects depend on the local environment and in particular
David Semrouni et al.
Journal of the American Society for Mass Spectrometry, 21(5), 728-738 (2010-03-02)
The structure of the sodiated peptide GGGGGGGG-Na(+) or G(8)-Na(+) was investigated by infrared multiple photon dissociation (IRMPD) spectroscopy and a combination of theoretical methods. IRMPD was carried out in both the fingerprint and N-H/O-H stretching regions. Modeling used the polarizable
Polyglycine acts as a rejection signal for protein transport at the chloroplast envelope
Endow JK, et al.
PLoS ONE, 11(12), e0167802-e0167802 (2016)

Artículos

Humankind has utilized protein materials throughout its existence, starting with the use of materials such as wool and silk for warmth and protection from the elements and continuing with the use of recombinant DNA techniques to synthesize proteins with unique and useful properties.

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico